Download Print this page

Specifications; Principle Of Operation - Emerson FISHER T208VR Series Instruction Manual

Advertisement

T208VR Series

Specifications

The Specifications section lists the specifications for T208VR Series Tank Blanketing Vacuum Regulator. Factory
specifications, such as maximum temperature, maximum inlet and outlet pressures, spring range, orifice size and
material and seat material are stamped on the nameplate fastened on the regulator at the factory.
Available Configurations
Type T208Vr: Direct-operated vacuum regulator
with internal pressure registration
Type T208VrM: Direct-operated vacuum regulator
with blocked throat and control line connection for
external pressure registration
Body Sizes and End Connection Styles
BODY SiZE
inch
Dn
gray cast iron
3/4 or 1
20 or 25
Maximum (Casing) Pressure
35 psig / 2.41 bar
Maximum (Casing) Vacuum Pressure
Full Vacuum
Maximum allowable Vacuum Pressure
See Table 1
Maximum Downstream Vacuum Pressure
Full Vacuum
1. The pressure/temperature limits in this Instructional Manual and any applicable standard or code limitation should not be exceeded.
!
Failure to follow these instructions or
to properly install and maintain this
equipment could result in an explosion,
fire and/or chemical contamination
causing property damage and personal
injury or death.
Fisher
vacuum regulators must be
®
installed, operated and maintained
in accordance with federal, state and
local codes, rules and regulations
and Emerson Process Management
regulator Technologies, inc. (regulator
Technologies) instructions.
if the vacuum regulator discharges
process fluid or a leak develops in
the system, service to the unit may be
required. Failure to correct trouble could
result in a hazardous condition.
Call a qualified service person to
service the unit. installation, operation
and maintenance procedures
2
(1)
EnD COnnECTiOn STYLES
316L/316 Stainless steel
NPT
NPT or CL150 RF
(1)
(1)
(1)
(1)
Warning
Vacuum Control Pressure ranges
See Table 1
Pressure registration
Type T208Vr: Internal
Type T208VrM: External
Orifice Size
7/16-inch / 11 mm
Control Line Connection
1/2 NPT
Material Temperature Capabilities
nitrile (nBr):
-20 to 180°F / -29 to 82°C
Fluorocarbon (FKM):
40 to 300°F / 4 to 149°C
Spring Case Connection
1/4 NPT
approximate Weight
19 pounds / 8.6 kg
performed by unqualified person may
result in improper adjustment and
unsafe operation. Either condition
may result in equipment damage
or personal injury. Only a qualified
person shall install or service the
T208Vr Series vacuum regulators.

Principle of Operation

The T208VR Series vacuum regulators (Figure 2)
are used to maintain a constant vacuum at the
regulator inlet. A decrease in this vacuum (increase
in absolute pressure) beyond this value registers on
the diaphragm and opens the disk. This permits a
downstream vacuum of lower absolute pressure than
the upstream vacuum to restore the upstream vacuum
to its original pressure setting. On the Type T208VR,
pressure registers underneath the diaphragm. The
Type T208VRM has a control line connecting the
diaphragm casing to the vacuum line and an O-ring
stem seal blocking the throat causing registration
pressure to flow through the control line.
(1)
(1)

Advertisement

loading

This manual is also suitable for:

Fisher t208vrFisher t208vrmFisher t208vr seriesT208vrm