Introduction
This installation guide provides instructions for
installation, startup and adjustment. To receive a copy of
the instruction manual, contact your local Sales Office or
view a copy at www.fisher.com. For further information,
refer to: Type T205B Balanced Tank Blanketing
Regulator Instruction Manual, D103750X012.
PED Categories
This product may be used as a safety accessory with
pressure equipment in the following Pressure Equipment
Directive categories. It may also be used outside of the
Pressure Equipment Directive using sound engineering
practice (SEP) per table below. For information on the
current PED revision see Bulletin: D103053X012.
PRODUCT SIZE
DN 20 and 25 / 3/4 and 1 in.
Specifications
Body Sizes and End Connection Styles
See Table 1
Maximum Allowable and Operating Inlet Pressure
See Table 1
Maximum Outlet (Casing) Pressure
See Table 1
Maximum Emergency Outlet Pressure to Avoid
Internal Parts Damage
With Nitrile (NBR) or Fluorocarbon (FKM)
diaphragm: 2.4 bar / 35 psig
With Fluorinated Ethylene Propylene (FEP)
diaphragm: 0.69 bar / 10 psig
Outlet (Control) Pressure Ranges
See Table 3
Shutoff Classification per ANSI/FCI 70-3-2004
Class VI (Soft Seat)
Material Temperature Capabilities
Elastomer Parts
Nitrile (NBR): -40 to 82°C / -40 to 180°F
Fluorinated Ethylene Propylene (FEP):
-29 to 82°C / -20 to 180°F
Fluorocarbon (FKM): 4 to 149°C / 40 to 300°F
Ethylene Propylene Diene (EPDM): -29 to 107°C /
-20 to 225°F
Perfluoroelastomer (FFKM): -18 to 149°C /
0 to 300°F
Body Materials
: -29 to 149°C / -20 to 300°F
Gray Cast Iron
(3)
WCC Carbon Steel: -29 to 149°C / -20 to 300°F
LCC Carbon Steel: -40 to 149°C / -40 to 300°F
CF8M/CF3M Stainless Steel: -40 to 149°C /
-40 to 300°F
1. The pressure/temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded.
2. See Table 2 for operating temperature ranges for available trim combinations.
3. For proper operation to achieve the published capacities at low setpoint, the spring case barrel should be installed pointed down as shown in Figure 1.
CATEGORY
FLUID TYPE
SEP
(1)
(1)
(1)
(1)(2)
Installation
Only qualified personnel shall install
or service a regulator. Regulators
should be installed, operated and
maintained in accordance with
international and applicable codes
and regulations and Emerson
Process Management Regulator
Technologies, Inc. instructions.
If the regulator vents fluid or a leak
develops in the system, it indicates that
service is required. Failure to take the
regulator out of service immediately
may create a hazardous condition.
1
Personal injury, equipment damage
or leakage due to escaping fluid
or bursting of pressure containing
parts may result if this regulator is
overpressured or is installed where
(1)
service conditions could exceed the
limits given in the Specifications
section, or where conditions exceed
any ratings of the adjacent piping or
piping connections.
To avoid such injury or damage, provide
pressure-relieving or pressure-limiting
devices (as required by the appropriate
code, regulation or standard) to
prevent service conditions from
exceeding limits.
Additionally, physical damage to the
regulator could result in personal injury
and property damage due to escaping
fluid. To avoid such injury and damage,
install the regulator in a safe location.
Clean out all pipelines before installation of the
regulator and check to be sure the regulator has not
been damaged or has collected foreign material during
shipping. For NPT bodies, apply pipe compound
to the external pipe threads. For flanged bodies,
use suitable line gaskets and approved piping and
bolting practices. Install the regulator in any position
desired
through the body is in the direction indicated by the
arrow on the body.
WARNING
!
, unless otherwise specified, but be sure flow
(3)
Type T205B

Advertisement

loading

Summary of Contents for Emerson Fisher T205B

  • Page 1 Regulator Instruction Manual, D103750X012. maintained in accordance with international and applicable codes PED Categories and regulations and Emerson This product may be used as a safety accessory with Process Management Regulator pressure equipment in the following Pressure Equipment Technologies, Inc. instructions.
  • Page 2 Type T205B Table 1. Body Sizes, End Connection Styles, Maximum Allowable and Operating Inlet Pressures and Maximum Outlet (Casing) Pressure MAXIMUM ALLOWABLE AND OP- MAXIMUM OUTLET BODY SIZE END CONNECTION ERATING INLET PRESSURE (CASING) PRESSURE BODY MATERIAL STYLES psig psig Gray Cast Iron 10.3 20 or...
  • Page 3 Type T205B EXTERNAL SQUARE HEAD ADJUSTING SCREW ASSEMBLY OPTION ERSA00627 APPLY LUBRICANT L1 = MULTI-PURPOSE PTFE LUBRICANT L2 = ANTI-SEIZE COMPOUND 1. Lubricants must be selected such that they meet the temperature requirements. 2. For 83 to 172 mbar / 1.2 to 2.5 psig, 0.17 to 0.31 bar / 2.5 to 4.5 psig and 0.31 to 0.48 bar / 4.5 to 7 psig spring ranges only. Figure 1.
  • Page 4 Technologies, Inc. All rights reserved. 06/20. McKinney, Texas 75070 USA Singapore 128461, Singapore The Emerson logo is a trademark and service mark of Emerson T +1 800 558 5853 T +65 6777 8211 Electric Co. All other marks are the property of their prospective owners.