White Balance
The white balance can be automatically adjusted once
when the WHITEBALANCE-AUTO command is
executed. The detection area is set to the screen center
by default. The detection area can also be displayed on
the screen. The detection frame can be changed
arbitrarily (AWB-FRAME). For manual correction, the
FINE command should be executed. The white balance
can be set finely per sensor tap. Therefore, a fine
adjustment should be made if the color difference
between sensor taps cannot be adjusted completely by
AWB.
command
param
WHITEBALANCE-
0
AUTO (AWB)
1
AWB-FRAME-
0
HIGHLIGHT
1
command
RGAIN-FINE
256 (×1) to 4095
GGAIN-FINE
256 (×1) to 4095
BGAIN-FINE
256 (×1) to 4095
For reference
If the color offset between the left and right sensor taps
cannot be cleared through fine adjustment using the
FINE command, adjustment of the black level may
work. Set the R, G, and B FINE levels to ×1 (256), align
the black levels, and then use the FINE command to
make fine adjustments. This tends to occur in low
temperature environments and when analog gain is set
high.
LUT
Five types of presets are provided. Specify using a 12 bit
value. Binarization, 5-point interpolation, and arbitrary
setting can be changed.
command
param
LUT-FORMAT
0
1
2
3
4
Setting
Manual correction
One-push AWB
Detection frame is hidden
Detection frame is
displayed
param
Setting
Red gain
Green gain
Blue gain
Setting
LUT off (γ=1)
Reverse
Binarization
5-point interpolation
Arbitrary setting
1. LUT off
2. Reverse
4. 5-point
5. Arbitrary setting
interpolation
Binarization
The binarization threshold can be changed.
command
BINARIZATION
0 to 2047 to 4095
5-point interpolation
The values of output points 1 through 5 that correspond
to input points 1 through 5 can be changed. Linear
interpolation is performed between interpolation points.
command
param1
LINEAR-
1 to 5
INTERPOLATION
Setting example:
Output
>LINEAR-INTERPOLATION 1 240 200
>LINEAR-INTERPOLATION 2 900 400
>LINEAR-INTERPOLATION 3 2047 3000
>LINEAR-INTERPOLATION 4 3000 3200
>LINEAR-INTERPOLATION 5 3800 3900
>LINEAR-INTERPOLATION-BUILD
>LUT-FORMAT 3
3. Binarization
param
param2
param3
0 to 4095
0 to 4095
Input
White Balance
31