Download  Print this page

Timing Chart; Horizontal Timing; Vertical Timing - Sony XCL-S600 Technical Manual

Digital video camera module.
Hide thumbs

Advertisement

Timing Chart

Horizontal timing

Constant regardless of the trigger mode, binning, and partial scanning. DVAL and LVAL are the same signal.
LVAL
DVAL
STROBE
Video output
sensor-tap
XCL-S600/C
XCL-S900/C
* When CAMERALINK-TAP=1. The value will be half during 2tap output.
Start time is shifted according to the OFFSETX value.

Vertical timing

Trigger
FVAL
LVAL
Video output
sensor-tap
XCL-S600/C
XCL-S900/C
E: Varies depending on the EXP, OFFSETY value or trigger latency.
28
Timing Chart
STROBE
1
54 MHz
3184*
2
84 MHz
2772*
4
84 MHz
2772
1
54 MHz
3872*
2
84 MHz
3402*
4
84 MHz
3402
C
1
24 + OFFSETX
2
13 + OFFSETX
4
13 + OFFSETX
1
24 + OFFSETX
2
13 + OFFSETX
4
13 + OFFSETX
A
B
WIDTH*
WIDTH*
WIDTH
WIDTH*
WIDTH*
WIDTH
D
3184 - WIDTH - C
2772 - WIDTH - C
2772 - WIDTH - C
HEIGHT / 2
3872 - WIDTH - C
3402 - WIDTH - C
3402 - WIDTH - C
HEIGHT / 2
n
HEIGHT
HEIGHT
HEIGHT
HEIGHT