Trigger Source; Trigger Inhibition - Sony XCL-S600 Technical Manual

Digital video camera module
Hide thumbs Also See for XCL-S600:
Table of Contents

Advertisement

Sequential
SP-TRG-MODE=2, SP-TRG-POL=0, SP-TRG-F-CNT=3 in the figure.
Trigger signal
Sensor output
Trigger states

Trigger source

This can be input via the DC IN connector, Digital IF connector, or software command (TRG-SOFT). Refer to "Trigger
Signal Input" (page 13) for details. Note that the trigger sources for the special trigger operation and the trigger mode
operation are defined separately.

Trigger inhibition

Trigger input can be disabled. This function is effective when disabling the trigger signal to a specific camera in the
environment where multiple cameras are connected by the same trigger signal and when preventing false operations
caused by noise contamination to the trigger signal line (due to the installed environment).
Trigger signal
Trigger inhibition
Exposure
Sensor output
command
TRG-INH
Exposure
Setting 1
5ms or
longer
Trigger mode
param
0
Trigger is accepted
1
Trigger is not accepted
Setting 2
Free run
Bulk
Sequential
Trigger
disabled
Setting
Setting 3
Trigger edge detection
Trigger width detection
Trigger Control
21