Trigger Delay; Trigger Counter; Frame Counter; Trigger Range Limit - Sony XCL-S600 Technical Manual

Digital video camera module
Hide thumbs Also See for XCL-S600:
Table of Contents

Advertisement

Trigger delay

The camera can delay the trigger signal.
When a trigger signal is input before the trigger delay time, or a trigger which contains noise is recognized, the image
cannot be displayed. This is not a malfunction.
Trigger signal
Exposure
Sensor output
command
param
TRG-DLY
0 to 4000000

Trigger counter

Accepted triggers by which video output is performed are counted. Triggers are counted up by the internal counter even
in the free-run operation. Setting 0 resets the counter. Video output is not performed for triggers that coincide with the
double exposure timing, but triggers are counted up. Triggers that have been removed by trigger range limit are not
counted. The trigger counter returns to 0 when the upper limit (2147483647) is reached.
command
TRG-CNT

Frame counter

The frame counter increases when an image is output. Setting 0 resets the counter. Frames whose image cannot be
output due to triggers that coincide with the double exposure timing are not counted. The trigger counter returns to 0
when the upper limit (2147483647) is reached.
command
FRAME-COUNTER

Trigger range limit

Only signals in the set trigger width can be accepted as the trigger signal. This functions as a noise filter, which removes
chattering or disturbance noise in the trigger signal line. This also functions as a trigger selector, whereby only a specific
camera can be operated by the trigger when multiple cameras share one trigger signal line. When the trigger signal is
input, exposure is started immediately to increment the trigger counter; however, when trigger width is out of the range,
video is not output and the trigger counter is decremented. If the shutter time is set shorter than the upper limit, triggers
will be received and video is output even if the trigger signal is wider than the trigger range limit. If the trigger source
is soft trigger, trigger range is not enabled.
command
TRG-RANGE
TRG-RANGE-LOWER
TRG-RANGE-UPPER
Setting
Trigger delay [µs]
param
0
Trigger range off
1
Trigger range on
10 to 2000000
Trigger range lower limit [µs]
10 to 2000000
Trigger range upper limit [µs]
Setting
23
Trigger Control

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xcl-s900Xcl-s600cXcl-s900c

Table of Contents