Trigger Delay; Trigger Counter; Trigger Range Limit - Sony XCU-CG160 Technical Manual

Digital video camera module
Table of Contents

Advertisement

Trigger delay

The camera can delay the trigger signal.
Trigger signal
Exposure
Sensor output
Feature
Parameter
TriggerDelay
0 to 4000000 Trigger delay [µs]

Trigger counter

This counts the number of accepted triggers. Triggers that have been removed because they exceed the trigger range
limit and triggers input with invalid timing are not counted. The trigger counter returns to 0 when the upper limit
(2147483647) is reached. The trigger counter can be reset to 0 by issuing TriggerCounterReset.
Feature
TriggerCounter
TriggerCounterReset

Trigger range limit

Only signals in the set trigger width can be accepted as a trigger signal. This functions as a noise filter, which removes
chattering or disturbance noise in the trigger signal line. When a trigger signal is input, exposure is started with a time
lag set by the trigger range set value. No image is output outside the trigger signal width set range.
Feature
TriggerAcceptanceRangeEnable
TriggerAcceptanceRangeLowerLimit
Trigger range operation example
ExposureTime=300, TriggerAcceptanceRangeLowerLimit=100 in the figure.
Trigger signal
Exposure
Sensor output
Setting
Parameter
False (0)
Trigger range off
True (1)
Trigger range on
1 to 2000000 Trigger range lower limit [µs]
100μ
20