Specifications
Manual reset pulse time
Automatic reset time
Start-up reset time
Response time
Input to output response time
Cross error detection time
Minimum PROFIsafe watchdog time
STO through PROFIsafe
PROFsafe version 2.4 supported
PROFIdrive version 3.00.4 supported
10.5 Safety Characteristic Data
European directives
Safety standards
10
10
Safety function
Safety performance
Table 10.1 Safety Characteristic Data
The safety-related characteristic data are valid for all safety
functions.
When calculating the safety characteristic data, consider all
units used within a safety function.
44
Safety Option MCB 152
Machinery Directive
(2006/42/EC)
EMC Directive
(2004/108/EC)
Low Voltage Directive
(2006/95/EC)
Safety of Machinery
Functional Safety
Safety Integrity Level
HFT (IEC 61508)
Subsystem Classification
Probability of Dangerous Failure
per Hour
Probability of Dangerous Failure
on Demand
Category
Performance Level
Mean Time to Dangerous Failure
of each Channel
Average Diagnostic Coverage
Safe Failure Fraction
Proof Test Interval
Danfoss A/S © 10/2014 All rights reserved.
10 µs (safety option and frequency converter)
EN ISO 13849-1
EN IEC 62061
EN IEC 61800-5-2
EN 50011
EN 61000-6-3
EN 61800-3
EN 50178
EN 61800-5-1
EN ISO 13849-1
IEC 62061
IEC 60204-1
IEC 61508-1 to -7
IEC 61800-5-2
IEC 61784-3
IEC 61800-5-2
Safe Torque Off (STO)
SIL 2
SIL CL2
Hardware Fault Tolerance = 1
Type B
PFH: 1,52 e-8
PFD: 1,33 e-3
Cat 3
PL d (cat 3)
MTTFd: 245 years (High)
DC
: 86% (Low)
ave
SFF: 90%
20 Years
≤10 ms (fieldbus)
≤4 ms
≤5 s (42-90 Restart Safe Option)
≤2 ms
≤3 ms (@activated output)
67 ms
23 ms
Yes
Yes
IEC 60204-1
Stop Category 0
MG37F102