EMERGENCIES: if a gas leak cannot be stopped, or a fire occurs due to gas leakage, call the fire department.
Gas leaking from
cracked!cut!burned
hose.
Gas leaking from LP
cylinder.
• Damaged hose.
• Mechanical failure due to rusting or
mishandling.
• Turn off gas at LPcylinder or at source on natural gas systems. If the hose
is cracked or cut but not burned, simply replace valve / hose / regulator.
If the hose is burned, the cause could be other than a faulty valve!hose!
regulator. Discontinue use of grill until a plumber or gas technician has
investigated and corrected the probtem.
•Repiace LPcylinder.
Gas leaking from LP
cylinder valve.
Gas leaking between LP
cylinder and regulator
connection.
Fire coming through
control panel.
excessive flames above
cooking surface.
• Failure of cylinder valve from mishandling
or mechanical failure.
• Improper instaNation, connection not
tight, failure of rubber seal.
• Fire in burner tube section of burner
due to blockage.
• Turn oft LPcylinder valve. Return LPcylinder to gas supplier.
• Turn off LPcylinder valve. Remove regulator from cylinder and visually
inspect rubber seat for damage. See LPCylinder Leak Test and Connecting
Regulator to the LPCylinder.
• Turn off control knobs and LPcylinder valve. Leave lid open to allow flames
to die down. After fire is out and grill is cold, remove burner and inspect
for spider nests or rust. See Spider Alert and Cleaning the Burner Assembly
sections of this Use & Care Guide.
to die down. After cooling, clean food particles and excess grease from
inside firebox area, grease tray, and other surfaces.
Troubleshooting
Burner(s)will not light
usingigniter. (See
Electronic Ignition
Troubleshootingalso)
° Trying to light wrong burner.
° Burner not engaged with control
valve,
° See instructionson control panel and in Use and Care section.
° Make surevalvesare positionedinsideof burnertubes.
° Obstruction in burner.
° Ensure burner tubes are not obstructed with spider webs or
other matter. See cleaning sectionof Use and Care.
° No gas flow.
° Make sureLPcylinder is not empty. If LPcylinder is not empty,
refer to "Suddendrop in gas flow."
° Vapor lock at coupling nut to LP
° Turnoff knobsand disconnectcoupling nutfrom LPcylinder.
cylinder.
Reconnectand retry.
° Couplingnut and LPcylinder valve not
° Turnthe coupling nutapproximately one-half to three-quarters
fully connected,
additional turn untilsolid stop. Tighten by hand only - do not use
tools.
° Electrode cracked or broken; '_sparks
° Replaceelectrode (s).
at crack.
° Electrode tip not in proper position.
Main Burners:
° Tip of electrode shouldbe pointingtoward gas port opening
on burner.Thedistance shouldbe 1/8" to 1/4".Adjust if
necessary.
° Wire and/or electrode covered with
• Clean wire and/or electrode with rubbing alcohol and clean
cooking residue,
swab.
° Wires are looseor disconnected.
° Reconnectwires or replace electrode/wire assembly.
° Wires are shorting (sparking)
° Replaceigniter wire/electrode assembly.
between igniter and electrode.
° Dead battery.
° Replacewith a new AAA-size alkaline battery.