7.3.

LIMITS

Limits can be set to indicate within limit, a warning limit or out of limit. Red/Green limit Led's and Audible Buzzer only active when button is pressed
to tag measurement.
7.3.1.
Red out of limit, Green within limit
7.3.2.
Flashes Red/Green when enabled. The warning limits can only be enabled by the controller.
7.3.3.
Single beep or 3 slow beeps can be selected for either in or out of l limit
The WHT can be set up so that the limit led's are as below
Off
In Limit
Out of Limit
In and Out of Limit
502848 Issue11 Wigauge User Leaflet
UPPER AND LOWER LIMITS
UPPER AND LOWER WARNING LIMITS **
AUDIBLE LIMIT
IN LIMIT
No Indication
Green
No Indication
Green
OUT OF LIMIT
No Indication
No Indication
Red
Red
WARNING, If ENABLED
No Indication
Red/Green
Red/Green
Red/Green