System Description; Intended Use; Field Of Application; System Components - ACS contsys Sonicont USN4SP Technical Manual

Ultrasonic level transmitter / level switch non-contact measurement of filling levels in liquids, pastes and coarse bulk materials
Table of Contents

Advertisement

1 System description

1 .1 Intended use

The device is an electronic level transmitter / level switch for monitoring, control as well as continuous
measurement of filling levels in liquids, pastes and coarse bulk materials.
Additional application fields are volume or flow measurement.
The operational reliability of the device is ensured only at the intended use.

1 .2 Field of application

Due to the device construction with
Measuring ranges of 2m / 5m / 8m
Process temperatures from –40°C to +85°C
Process materials PVDF / CrNi-steel / EPDM
as well as the availability of extensive equipment and functionality
Predefined vessel types for fast commissioning
Predefined linearization curves for volume and flow measurement
Integrated error signal suppression for adaption the installation situation
Integrated compensation of the process temperature
Limit value function for two-point control
Pump control function
Impulse output function for quantity counter
Error indication function for error monitoring
the device is especially suitable for the use for
Level and volume measurement
Flow measurement at open channels and measuring weirs
for
Water and waste water sector
Process industry
Environmental technology
Storage tanks, storage bunkers, silos
The device is suitable for demanding measuring requirements.
Due to its high accuracy and the high flexibility of configuration, the device can be suited a wide
variety of applications.
The robust design and the high-quality workmanship turns the device into a very high quality product,
which even the most adverse environmental conditions cannot affect, whether low temperatures when
used outdoors, high shock and vibration or aggressive media.
A captive laser marking of the type label ensures the identifiability throughout the entire lifetime of
the device.
Obviously is the optional marking of a measurement point designation resp. TAG, a customer label or
of a neutral type label, of course also per laser marking.
A LABS-free resp. silicone-free version, a factory calibration with calibration certificate and a customer
specific configuration resp. preset is also optionally available like a material test certificate EN10204
3.1.
Customer specific special versions can be realized on request, e.g.
software adaption (menu navigation, special functions, etc.),
changed terminal assignment resp. connector orientation,
design adaption of the user surface,
special designs for the process connection

1 .3 System components

The device consists on the components:
Sensor tip with ultrasonic sensor and temperature sensor.
Process connection, for installation into the container cover or a bracket.
Terminal enclosure, rotatable by 300°, for protection of the integrated signal processing
electronic and for the electrical connection.
The components cannot be separated by the user.