This document provides a copy of the parts Exploded View Diagram and Parts Identification
List that you can use as a quick reference, see
vicers go to the Precor Partner website
parts information.
.
Cleaning Solutions
Wipe down equipment with recommended cleaning solution. Use dry cloth to remove residue
solution.
General: 1 oz. mild soap to 30 oz. water (Ex. Simple Green).
l
Console and PVS: a diluted solution of one part 91% Isopropyl alcohol to one part
l
water.
CAUTION: Do not use acidic cleaners and do not spray directly onto the equipment
surfaces.
Electrical Requirements
Each P82 utilize an external 12 VDC / 50 W power supply.
The power supply AC input is plugged into the facility AC power outlet and the supply output
cable is connected to the console power input connector except for treadmills.
For treadmill installations, The power supply input power is hardwired to the line filter output
and the earth ground is directly connected to the line filter chassis ground tab (a power supply
adapter wire bundle is included with treadmill P82 installations).
CAUTION: A maximum of 10 consoles can be connected to one 20-amp dedicated
branch circuit. If the branch circuit has any other devices connected, the number of
P82 consoles must be reduced by the wattage of the other devices. .
Input Power
Console input: 12 VDC nominal (range: 8 VDC - 16 VDC), 50 W nominal (60 W max)
Ext Power Supply input: 100 - 240 VAC / 15 or 20 Amp
Earth ground requirements
Self-powered equipment (EFX, AMT & Bikes): The earth ground is connected from the
l
facility power outlet earth ground through the power supply brick.
P82 Console
"Parts" on
page 79. It is recommended that ser-
Precor Partner Website
2 General Information
Cleaning Solutions
to access the most current
12