3.4
THERMOCOUPLES
3.4.1 Oven Thermocouple
To replace, undo oven control panel fixings and slide out as detailed in Section 3.2.1. Remove
burner chamber grille and RH side panel (see Section 3.2.5) Undo nuts securing thermocouple at
control valve and at pilot. Withdraw through hole in oven wall. When replacing a thermocouple, do
not bend to less than 15mm radius, and ensure that connections are soundly made taking care not
to over-tighten valve nut. (Finger tight + quarter turn).
3.4.2 Open Top Thermocouple (G2102 C only)
Remove hob as detailed in Section 3.2.3.
Remove nut securing thermocouple to burner support bracket and pull thermocouple through
support bracket from underside.
Undo thermocouple connection at FFD section of gas tap and carefully remove thermocouple from
hob. Repeat for all hob burners.
Replace in reverse order taking care to position tip correctly in relation to burner ports.
Thermocouple tip should be 34mm above support bracket. Ensure tip does not touch burner cap
when fully re-assembled.
3.5
OVEN PIEZO UNIT
The piezo unit is secured to oven control panel.
Open oven control panel as detailed in Section 3.2.1.
Remove ignition lead and undo fixing at control panel rear.
Replace in reverse order.
3.6
OVEN PILOT BURNER ASSEMBLY
Withdraw oven control panel and remove burner chamber grille.
Undo rear nuts securing pilot supply tube and thermocouple. Pilot injector will be released, take
care not to lose it. Remove spark electrode lead.
Remove screws securing pilot bracket.
Remove pilot burner with mounting bracket.
If desired, pilot burner can now be dismantled from bracket by removing two fixings.
Replace in reverse order.
3.7
REMOVAL and CLEANING of BURNERS
3.7.1 Oven Burner
To Remove
Withdraw oven control panel as detailed in Section 3.2.1 and remove burner chamber grille.
Remove pilot burner assembly as detailed in Section 3.6.
From inside control chamber, release compression fitting nut on burner feed-pipe.
Remove fixings securing main burner bracket to oven base frame.
Remove burner complete with mounting bracket, slightly left to clear pipe, then remove from front.
To Clean
Remove all accumulated debris from burner by lightly brushing, afterwards shaking or blowing
clean.
Replace in reverse order.