SMD Rework Station Instruction Manual Thank you for purchasing the HAKKO FR-810B SMD Rework Station. This unit features digital control and display of hot air temperature. Please read this manual before operating the HAKKO FR-810B. Keep this manual readily accessible for reference.
● Do not modify the unit. ● Use only genuine HAKKO replacement parts. ● Do not allow the HAKKO FR-810B to become wet, or use it when hands are wet. ● Remove the power cord by holding the plug - not the cord.
4. INITIAL SETUP ● Controls and displays The front panel of HAKKO FR-810B includes five operation buttons. - Used to start or stop the station. •Pressing this button when the forced cool down bypass is enabled will turn the airflow off and stop the cooling process.
Page 5
These nozzles could not be attached to HAKKO FR-810B when the vacuum pipe is extended. Do not use excessive force. A1124, A1142 Do not use these nozzles with HAKKO FR-810B. These nozzles do not have space to blow hot air, using them with the HAKKO FR-810B may result in danger.
The rim of the C. Electrical connection and power ON handpiece must rest on the area 1. Insert the power cord into the receptacle on circled in the the rear panel of the station. illustration. 2. Place the handpiece on the holder. 3.
● Setting/Changing the Temperature and Timer NOTE: After accepting the value for the ones digit for temperature, you will have the option to set the timer starting over with the hundreds digit. The factory default : "Temperature 600℉" "Timer ーーー (No setting)" Example : When the set temperature is 300°C and the timer setting is ---.
● Preset mode In addition to the procedure described remove above, HAKKO FR-810B includes a preset mode allowing the selection of temperature, time, and airflow from the options you define (up to 5 temperature/time/airflow settings can be programmed). Enter the parameter setting to change the mode.
The letters Select and input three letters for password for password from six letters on the right. Example: The procedure for changing the set temperature when the unit is restricted by a password. (Password is "AbC") Press and hold the Press the Press the button for more...
Pressing the button once allows you to check the settings of the set temperature and set time in this order. 6. PARAMETER SETTING The HAKKO FR-810B has the following parameters: Parameter name Parameter No. Value Initial value ℃ / ℉ selection ℉...
Page 11
● :℃ or ℉ temperature display seletion The displayed temperature can be switched between Celsius and Fahrenheit. ● :Auto sleep ON/OFF setting Select whether you will activate the auto sleep function. ● :Auto shutoff ON/OFF setting Select whether you will activate the auto shut off function. ● :Setting mode selection Temperature setting can be switched between the normal mode and the preset mode.
Page 12
● Parameter entering mode 1. Turn off the power switch. 2. Turn on the power switch while pressing the button. 3. When the display shows , the station is in parameter entering mode. 4. You can switch the parameter No. by pressing the A.
E. Password setting 1. Either will be displayed if you press the button when is displayed. 2. If you press the ) button, (Open), (Partial) and (Restricted) will be switched alternately. 3. If you press the button after selecting, the display will return to .
Page 14
F. Auto shutoff time setting 1. Auto shutoff time (30 minutes early) will be displayed if you press the button when is displayed. 2. Press the ) button, you can change to the desired value. The values you can enter is 30 to 60 (minutes). 3.
● The temperature distribution charts for HAKKO 850 or 850B should not be used for HAKKO FR-810B. HAKKO FR-810B uses a different pump and control system. When you use the HAKKO FR-810B, make sure to refer to the temperature distribution charts shown to the under.
Page 16
N51-02 Single ø4.0 (0.16) ℃ (1292℉) ℃ ⑥ (1112℉) ℃ ⑤ (932℉) ℃ ④ (752℉) ℃ ③ (572℉) ℃ ② ①100℃ (392℉) ②200℃ ③300℃ ① ℃ ④400℃ (212℉) ⑤500℃ ⑥600℃ ℃ (32℉) N51-03 Single ø5.5 (0.22) ℃ (1292℉) ℃ ⑥ (1112℉) ℃...
Page 17
N51-04 Single ø7.0 (0.28) ℃ (1292℉) ℃ (1112℉) ⑥ ℃ (932℉) ⑤ ℃ ④ (752℉) ③ ℃ (572℉) ② ℃ ①100℃ (392℉) ②200℃ ① ③300℃ ℃ ④400℃ (212℉) ⑤500℃ ⑥600℃ ℃ (32℉) N51-05 Bent Single 1.5 x 3 (0.06 x 0.12) ℃...
8. MAINTENANCE / INSPECTION CAUTION Replacing the heating element is very dangerous. Be sure to turn the power switch OFF and be careful of the following procedure when replacing the heating element. A. Remove the heating element CAUTION When replacing the heater, please be careful not to apply force, such as vacuum pipe is bent. 1.
9. ERROR MESSAGE When the error detection software in the HAKKO FR-810B detects an error, a message is displayed to alert the operator. See “Troubleshooting” for procedures to correct the error. This error occurs when there is the possibility of a sensor failure (or a ●...
⑧ B5060 Fuse/250V-6.3A 220-240V B5048 Handpiece holder ⑨ B5108 P.W.B. / 100-127V ⑩ B5109 P.W.B. / 220-240V B5052 ● HAKKO FR-810B ⑪ Item No. Part No. Part Name Specifications B5053 Power unit ⑫ A5005 Heating element assembly 100-110V B5054 Power cord, 3 wired cord & American plug U.S.A.
Page 21
● Optinal Parts Item No. Part No. Part Name Specifications B5059 Adapter/ for fixture(C1392B) ① ×2 B5126 Air guard assembly ② With fixing bracket ● Assembly of the air guard ② ① Screws Air guard (with the air guard assembly assembly) Attach the air guard assembly.
Page 22
12. OPTIONAL PARTS (Nozzle) ● Straight nozzle N51-01 Single ø2.5 (0.1) N51-02 Single ø4 (0.16) N51-03 Single ø5.5 (0.22) N51-04 Single ø7 (0.28) N51-05 Bent single 1.5×3 (0.06×0.12) N51-06 Bent single ø5.5 (0.22) ● BGA nozzle N51-10 BGA 4 × 4 N51-11 BGA 6 ×...
Page 23
■ Accessories ● Combining with other products The HAKKO FR-810B can be combined with the following products for operation as a rework system. For usage details, please refer to the instruction manual for each product. Board holder HAKKO FR-870B When you use the HAKKO FR-870B and the board Grip Fixture L holder together, please remove the flat frame.
13. OPTIONAL PARTS (Accessories) ① O ring Hex wrench O ring (6 across flats) Hex wrench (6 across flats) Tray ③ ④ Item No. Part No. Part Name Specifications C5027 Board holder ① C5028 Grip Fixture M ② C5029 Grip Fixture L ③...