5 Commonwealth Ave Woburn, MA 01801 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com SMD Rework Station Instruction Manual Thank you for purchasing the HAKKO FR-810B SMD Rework Station. This unit features digital control and display of hot air temperature. Please read this manual before operating the HAKKO FR-810B.
3. WARNINGS, CAUTIONS AND NOTES Warnings, cautions and notes are placed at critical points in this manual to direct the operator’s attention to significant items. They are defined as follows: WARNING: Failure to comply with a WARNING may result in serious injury or death. CAUTION : Failure to comply with a CAUTION may result in injury to the operator, or damage to the items involved.
4. INITIAL SETUP ● Controls and displays The front panel of HAKKO FR-810B includes five operation buttons. - Used to start or stop the station. •Pressing this button when the forced cool down bypass is enabled will turn the airflow off and stop the cooling process. - Used for changing values.
Page 5
2. Attach the pad. a. Attach the pad. b. Adjust the pad to an appropriate position. Adjust the vacuum pipe so that the pipe and pad protrude as little as possible. CAUTION ● Pad The pad does not last indefinitely. When it becomes deteriorated, replace it. Since exposure to high temperatures causes it to deteriorate faster, Hakko recommends it be cooled after use.
The rim of the C. Electrical connection and power ON handpiece must rest on the area 1. Insert the power cord into the receptacle on circled in the the rear panel of the station. illustration. 2. Place the handpiece on the holder. 3. Plug the other end of the power cord into CAUTION a grounded wall socket.
● Setting/Changing the Temperature and Timer NOTE: After accepting the value for the ones digit for temperature, you will have the option to set the timer starting over with the hundreds digit. The factory default : "Temperature 600℉" "Timer ーーー (No setting)" Example : When the set temperature is 300°C and the timer setting is ---.
● Preset mode In addition to the procedure described remove above, HAKKO FR-810B includes a preset mode allowing the selection of temperature, time, and airflow from the options you define (up to 5 temperature/time/airflow settings can be programmed). Enter the parameter setting to change the mode. (Please refer to [6.
The letters Select and input three letters for password for password from six letters on the right. Example: The procedure for changing the set temperature when the unit is restricted by a password. (Password is "AbC") Press and hold the Press the Press the button for more...
● Auto shutoff function The auto shutoff function works by default after the station is idle for 30 minutes and it automatically enters a power save state. ● Forced cooling bypass function With this function enabled, if you press the “S” button ( button) again during cooling, cooling is stopped.
:℃ or ℉ temperature display seletion ● The displayed temperature can be switched between Celsius and Fahrenheit. :Auto sleep ON/OFF setting ● Select whether you will activate the auto sleep function. :Auto shutoff ON/OFF setting ● Select whether you will activate the auto shut off function. :Setting mode selection ●...
Page 12
● Parameter entering mode 1. Turn off the power switch. 2. Turn on the power switch while pressing the button. 3. When the display shows , the station is in parameter entering mode. 4. You can switch the parameter No. by pressing the A.
Page 13
E. Password setting 1. Either will be displayed if you press the button when is displayed. 2. If you press the ) button, (Open), (Partial) and (Restricted) will be switched alternately. 3. If you press the button after selecting, the display will return to .
Page 14
F. Auto shutoff time setting 1. Auto shutoff time (30 minutes early) will be displayed if you press the button when is displayed. 2. Press the ) button, you can change to the desired value. The values y ou can enter is 30 to 60 (minutes). 3. The display will return to if you press the button after selecting.
7. TEMPERATURE DISTRIBUTION CHART CAUTION ● These charts do not define the temperature characteristics, and are for reference only. ● The temperature distribution charts for HAKKO 850 or 850B should not be used for HAKKO FR-810B. HAKKO FR-810B uses a different pump and control system. When you use the HAKKO FR-810B, make sure to refer to the temperature distribution charts shown to the under.
Page 16
N51-02 Single ø4.0 (0.16) ℃ (1292℉) ℃ ⑥ (1112℉) ℃ ⑤ (932℉) ℃ ④ (752℉) ℃ ③ (572℉) ℃ ② ①100℃ (392℉) ②200℃ ③300℃ ① ℃ ④400℃ (212℉) ⑤500℃ ⑥600℃ ℃ (32℉) N51-03 Single ø5.5 (0.22) ℃ (1292℉) ℃ ⑥ (1112℉) ℃...
Page 17
N51-04 Single ø7.0 (0.28) ℃ (1292℉) ℃ (1112℉) ⑥ ℃ (932℉) ⑤ ℃ ④ (752℉) ③ ℃ (572℉) ② ℃ ①100℃ (392℉) ②200℃ ① ③300℃ ℃ ④400℃ (212℉) ⑤500℃ ⑥600℃ ℃ (32℉) N51-05 Bent Single 1.5 x 3 (0.06 x 0.12) ℃...
8. MAINTENANCE / INSPECTION CAUTION Replacing the heating element is very dangerous. Be sure to turn the power switch OFF and be careful of the following procedure when replacing the heating element. A. Remove the heating element CAUTION When replacing the heater, please be careful not to apply force, such as vacuum pipe is bent. 1.
9. ERROR MESSAGE When the error detection software in the HAKKO FR-810B detects an error, a message is displayed to alert the operator. See “Troubleshooting” for procedures to correct the error. This error occurs when there is the possibility of a sensor failure (or a ●...
11. PARTS LIST ④ ⑥ ① ② ⑤ ①,② ③ ⑫ ⑭ ⑧ ⑧ ⑪ ⑮ ⑦ ⑯ ⑩ ⑬ ⑨ Item No. Part No. Part Name Specifications B5043 Joint hose ⑦ B5044 Fuse/250V-10A 100-127V ⑧ B5060 Fuse/250V-6.3A 220-240V B5048 Handpiece holder ⑨...
Page 21
● Optinal Parts Item No. Part No. Part Name Specifications B5059 Adapter/ for fixture(C1392B) ① ×2 B5126 Air guard assembly ② With fixing bracket ● Assembly of the air guard ② ① Screws Air guard (with the air guard assembly assembly) Attach the air guard assembly.
Page 22
12. OPTIONAL PARTS (Nozzle) ● Straight nozzle N51-01 Single ø2.5 (0.1) N51-02 Single ø4 (0.16) N51-03 Single ø5.5 (0.22) N51-04 Single ø7 (0.28) N51-05 Bent single 1.5×3 (0.06×0.12) N51-06 Bent single ø5.5 (0.22) ● BGA nozzle N51-10 BGA 4 × 4 N51-11 BGA 6 ×...
Page 23
■ Accessories ● Combining with other products The HAKKO FR-810B can be combined with the following products for operation as a rework system. For usage details, please refer to the instruction manual for each product. Board holder HAKKO FR-870B When you use the HAKKO FR-870B and the board Grip Fixture L holder together, please remove the flat frame.
13. OPTIONAL PARTS (Accessories) ① O ring Hex wrench O ring (6 across flats) Hex wrench (6 across flats) Tray ③ ④ Item No. Part No. Part Name Specifications C5027 Board holder ① C5028 Grip Fixture M ② C5029 Grip Fixture L ③...