Loc 2 –7 When Phone Fault Is Detected
Location 2
(Phone fault detected) 16 segments of Feature Selection Data
Reporting must be enabled in the control panel for this location to function
properly.
This location selects the partition(s) to include when reporting to the Central Station. To exclude any
partition from reporting, simply turn off the LED corresponding to that particular partition. Using Table
XI-1 enter the corresponding number of the partition(s) to include for each type of report found in
Segments 1 –16. Factory default is all partitions ON for Segment 1; All partitions are defaulted OFF
for Segments 2 -16.
Table XI-1
1 = Partition 1
2 = Partition 2
SEGMENT
Alarms
1
Open/Close
2
Bypass
3
Zone Trouble
4
Power Trouble (AC Failure or
5
Low Battery)
Siren & Telephone Fault
6
Test Reports
7
Program, Download & Log Full
8
Location 3
(Phone fault detected) 8 segments of Feature Selection Data
This location selects the partition(s) to include when reporting Special Events to the Central Station.
To exclude any partition from reporting, simply turn off the LED corresponding to that particular
partition. Using Table XI-1 on page 12, enter the corresponding number of the partition(s) to include
for each type of report found in Segments 1 – 8. Factory default is all partitions ON for Segments 2
and 4; all partitions OFF for Segments 1 and 3.
SEGMENT
Alarm Restores
1
Telephone Fault
2
Start Download
3
Fail to Communicate, Data Lost
4
Reserved
5-8
12
Events To Report To Central Station
3 = Partition 3
4 = Partition 4
DESCRIPTION
Special Events To Report To Central Station
DESCRIPTION
5 = Partition 5
6 = Partition 6
SEGMENT
Tampers
9
Short Circuit & Ground Fault
10
Sensor Lost
11
Sensor Low Battery
12
Expander Trouble
13
Failure To Communicate
14
Zone Activity Monitor
15
Reserved
16
7 = Partition 7
8 = Partition 8
DESCRIPTION