Loc 8 –13 When Phone Line Is Good
Location 8
(Phone line is good)
Reporting must be enabled in the control panel for this location to function
properly.
This location selects the partition(s) to include when reporting to the Central Station when the phone
line is good. To exclude any partition from reporting, simply turn off the LED corresponding to that
particular partition. Using Table XI-1 enter the corresponding number of the partition(s) to include for
each type of report found in Segments 1 –16. Factory default is all partitions OFF.
SEGMENT
Alarms
1
Open/Close
2
Bypass
3
Zone Trouble
4
Power Trouble (AC Failure or
5
Low Battery)
Siren & Telephone Fault
6
Test Reports
7
Program, Download & Log Full
8
Location 9
(Phone line is good)
This location selects the partition(s) to include when reporting Special Events to the Central Station
when the phone line is good. To exclude any partition from reporting, simply turn off the LED
corresponding to that particular partition. Using Table XI-1 on page 12, enter the corresponding
number of the partition(s) to include for each type of report found in Segments 1 – 8. Factory default
is all partitions OFF.
SEGMENT
Alarm Restores
1
Telephone Fault
2
Start Download
3
Fail to Communicate, Data Lost
4
Reserved
5-8
Location 10
(Phone line is good)
Reporting must be enabled in the control panel for this location to function
properly.
This location selects the partition(s) to include when reporting to email when the phone line is good.
To exclude any partition from reporting, simply turn off the LED corresponding to that particular
partition. Using Table XI-1 on page 12, enter the corresponding number of the partition(s) to include
for each type of report found in Segments 1 –16. Factory default is all partitions OFF
NX-591E
Events To Report To Central Station
16 segments of Feature Selection Data
DESCRIPTION
Special Events To Report To Central Station
8 segments of Feature Selection Data
DESCRIPTION
Events To Report To Email
16 segments of Feature Selection Data
SEGMENT
Tampers
9
Short Circuit & Ground Fault
10
Sensor Lost
11
Sensor Low Battery
12
Expander Trouble
13
Failure To Communicate
14
Zone Activity Monitor
15
Reserved
16
DESCRIPTION