XI.

PROGRAMMING INSTRUCTIONS

Location 0
This location contains the System Identification Number (SID). Factory default is 0-0-0-0-0 for
AutoSID.
Location 1
Segment 1 contains the options to be programmed for the functioning of this module. Factory default
for all options is OFF.
Option
Format
1
2
Test Signal
System Preference
3
4
"B" Side Preference
Alternate MIN
5
6
Disable Cellular Service LEDs
Enable Tamper Switch
7
8
Disable SIA DCS Area
Modifier
Notes:
Daily test will be performed 24 hours (+/- 10 minutes) from time this option is programmed.
Weekly test will be performed 168 hours (+/- 10 minutes) from time this option is programmed.
Some older SIA DCS compatible receivers may not support the use of area (partition) modifiers.
In such cases, the area modifier must be disabled (Option 8 ON).
Segment 2 programs for Host Acknowledgement requirements. Factory default for all options is
OFF.
Option
1
Central Station messages
Email messages
2
3
Pager messages
Periodic test signals
4
5-8
Reserved
Segments 3 and 4 are reserved for future use.
NX-591E
Programming the Mode
5 segments Numeric Data
Feature Selection
4 segments Feature Selection Data
Description
Description
ON
SIA
Daily
Use "A" or "B" side only
"B" Side (if Opt 3 is ON)
Disabled
Disabled
Enabled
Disabled
ON
Enabled
Enabled
Enabled
Enabled
OFF
Contact ID
Weekly
No Preference
"A" Side
Enabled
Enabled
Disabled
Enabled
OFF
Disabled
Disabled
Disabled
Disabled