  • Page 1 Technical manual Xenon beacon XB15...
  • Page 2 ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to...
  • Page 3: Table Of Contents

    EN54-23:2010 visual alarm device – beacon XB15 (24Vdc units only) .......
  • Page 4 Xenon beacon Xb15 TM332 Issue A October 2018 www.eaton.com...
  • Page 5: Introduction

    M8 screw MEDC recommends that all cables and cores should or bolt. be correctly identified. Please refer to the wiring diagram in this manual (or separate diagram provided with the unit). Xenon beacon Xb15 TM332 Issue A October 2018 www.eaton.com...
  • Page 6: Access To Terminals

    Re-tighten the grub screw (2.0mm A/F hexagon key) in the cover flange to secure the cover. Wiring detail * Relay initiate option is not available for EN54-23 version Xenon beacon Xb15 TM332 Issue A October 2018 www.eaton.com...
  • Page 7: Operation

    O-ring. acids and alkalis as most metal products. However, if abnormal or unusual environmental conditions occur due to plant damage or accident etc., then visual inspection is recommended. Xenon beacon Xb15 TM332 Issue A October 2018 www.eaton.com...
  • Page 8: Removing/Replacing Xenon Tube

    89/106/EEC, along with the name Where Db signifies suitability for use in a Zone 21 surface and number of the notified body issuing the certificate industries area in the presence of dust. of conformity. Xenon beacon Xb15 TM332 Issue A October 2018 www.eaton.com...
  • Page 9: These Units Also Have The Following Approvals

    0.4 lux. Introduction Tip: To convert the coverage diameter y to the width of a The XB15 Beacon has been designed for use in potentially square room. explosive atmospheres and harsh environmental Width of square room = y/1.414 m.
  • Page 10: Assessment Of Functional Safety - Xb15 Dc

    Limited to: SIL 1 (1oo1) & SIL 2 (1oo2) due to SFF value. Assessment of functional safety – XB15 AC Analysis (FMEDA) of the XB15 Xenon Beacon against the requirements of IEC 61508-2 using a Proof Test Interval of This Beacon is intended for use in a safety system 8760hrs.
  • Page 11 Route 1 Systematic safety integrity compliance Route 1 Systematic Capability (SC1, SC2, SC3, SC4) Hardware safety integrity achieved Limited to: SIL 1 (1oo1) & SIL 2 (1oo2) due to SFF value. Xenon beacon Xb15 TM332 Issue A October 2018 www.eaton.com...
  • Page 12: Conditions Of Safe Use

    In all against common cause failures and independence other applications it is strongly recommended to test from cascading failures. the product at least once a year. Xenon beacon Xb15 TM332 Issue A October 2018 www.eaton.com...
  • Page 13 Avaliação da segurança funcional – XB15 DC ........
  • Page 14: Introdução

    à aplicação em rosca M8. questão. A MEDC recomenda que todos os cabos e condutores sejam identificados corretamente. Consulte o esquema elétrico reproduzido neste manual (ou o esquema separado fornecido com a unidade). Xenon beacon Xb15 TM332 Issue A October 2018 www.eaton.com...
  • Page 15: Acesso Aos Terminais

    Aperte novamente os parafusos Allen (chave hexagonal A/F de 2,0 mm) no flange da tampa para prendê-la firmemente. Detalhes da fiação * Opção iniciar transmissão indisponível para a versão EN54-23. Xenon beacon Xb15 TM332 Issue A October 2018 www.eaton.com...
  • Page 16: Funcionamento

    Perfluorolube 22/6 da Performance Fluids Ltd., a fim de produtos metálicos. evitar danos ao O-ring. Todavia, recomenda-se uma inspeção visual caso aconteçam condições ambientais anormais ou incomuns decorrentes de danos na instalação ou acidentes etc. Xenon beacon Xb15 TM332 Issue A October 2018 www.eaton.com...
  • Page 17: Remoção/Substituição Do Tubo De Xenônio

    Diretiva 89/106/EEC, juntamente com o nome e número Onde Db significa adequado para uso em áreas industriais do organismo notificado que emitiu o certificado de de superfície de Zona 21 na presença de poeira. conformidade. Xenon beacon Xb15 TM332 Issue A October 2018 www.eaton.com...
  • Page 18: Essas Unidades Também Dispõem Das Seguintes Aprovações

    A função de segurança do sinalizador luminoso é proporcionar uma luz de advertência visual esférica intermitente quando a tensão correta é aplicada à unidade. As versões DC do sinalizador luminoso são Xenon beacon Xb15 TM332 Issue A October 2018 www.eaton.com...
  • Page 19: Avaliação Da Segurança Funcional - Xb15 Dc

    (FMEDA) da Em condições de ausência de falha operacional versão DC do sinalizador luminoso de xenônio XB15 em (Normal), o sinalizador luminoso XB15 emitirá uma luz de relação aos requisitos da norma IEC61508-2 usando um advertência visual esférica quando exigido pelo sistema.
  • Page 20: Avaliação Da Segurança Funcional - Xb15 Ac

    Xenon beacon XB15 Português Brasileiro Avaliação da segurança funcional – XB15 AC de xenônio XB15 em relação aos requisitos da norma IEC61508-2 usando um intervalo de teste de prova de Este sinalizador luminoso destina-se a uso em um 8760 horas.
  • Page 21: Condições De Uso Seguro

    As condições a seguir se aplicam à instalação, operação geral, manutenção e reparo apenas deverá ser e manutenção do XB15. A falha em observá-las pode realizada por pessoal competente, observando todas comprometer a integridade de segurança do sinalizador as condições e recomendações do fabricante na...
  • Page 22 Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval Eaton by Eaton. The same applies to Trademarks (especially Eaton, Moeller, EMEA Headquarters and Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton Internet pages and Eaton order confirmations.