7.2.4

Membrane protection

The membrane achieves its optimal life with regular water flow or flushing.
If the HydroPower RO is not in use for an extended period of time (longer than 7 days), the membrane
must be protected against blockage.
For this purpose, there is the UNGER Membrane Care Agent (Order No. 15436). You need one bottle (1l) for
each membrane. This preserves the current state of the membrane and prevents reduced performance
and/or damage after sitting for a longer period of time. Alternatively, you can run the unit once a week for
approx. 30 minutes to rinse the membranes.
To protect the membrane, proceed as follows:
1. Switch off the HydroPower RO and disconnect the
power supply.
2. Drain the water from the HydroPower RO.
Unscrew all filter top caps and open the pressure relief
valve on the back of the HydroPower RO until no more
water leaks out.
3. Close the pressure relief valve and screw the yellow
cap onto the concentrate outlet.
4. Remove the pre-filter and resin filter cartridges and
store them protected from dust and dirt.
5. Pour one bottle of membrane care liquid (1l) into each
of the mebrane tanks.
6. Fill all tanks (#1 pre-filter + both membranes #2, #3)
with tap water until all three tanks have filled just
below the top edge. Tank #4 can remain without water.
7. Close all four tanks.
The membranes are protected and the HydroPower RO
3
can be stored.
30
Maintenance and servicing
Maintenance and maintenance plan
CAUTION
Irritation to eyes, skin and respiratory tract through membrane care
possible.
Avoid any contact and swallowing of the membrane care fluid.
`
In case of contact with eyes, remove contact lenses and rinse
`
immediately with plenty of water.
Keep the membrane care product sealed and inaccessible to children.
`
Wear protective gloves and goggles.
`
www.ungerglobal.com
Re-commissioning
1. Unscrew all 4 filter top caps.
2. Drain the water: Unscrew the yellow cap and
assemble the concentrate hose.
Now open the pressure relief valve at the rear.
3. Insert the filters. Pay attention to the correct
position (see page 33).
4. Screw the top-caps back on and start the
system.
5. The membrane care liquid is automatically
rinsed out and the resin filter is protected by
the by-pass process.