Controls, Buttons And Switches; The Manometer; The Settings Menu - unGer Hydro Power RO System RO40C Operating Instructions Manual

Table of Contents

Advertisement

Operation of the HydroPower RO

Controls, buttons and switches

5.2
Controls, buttons and switches
1 2 3
The navigation in the setup menu is done with the arrow keys next to the display. The current selection is
highlighted in yellow. You can confirm a value or a function with the ENTER key. Press the STOP button to
exit the setting menu.
5.3

The manometer

5.4

The settings menu

1
Manometer
2
Filter selection buttons
- PRE: Carbon/sediment combi pre-filter
- RO 1: RO membrane 1
- RO 2: RO membrane 2
- DI: DI resin filter
4
3
Display
4
STOP button
5
5
On / Off knob
The manometer shows the water pressure on the
membranes when the pump is running.
Ensure that the water pressure is at least 1 bar. The
optimum is 4 bar, maximum should not exceed 6 bar.
The pump increases the pressure by approx. 4 bar.
Accordingly, the pressure in operation should not exceed 10
bar.
At a pressure of 10.5 bar, the pressure relief valve opens
automatically at the rear.
To enter the settings menu, proceed as follows:
1. Stop the HydroPower RO with the STOP button.
2. Press the ENTER button to enter the settings menu.
You can now view or change all settings.
3
The main menu allows you to view or change various
parameters such as units of measurement, time / date,
information, software status etc.
www.ungerglobal.com
Quality Tools for Smart Cleaning