7. The system is automatically initialized. The resin is
first by-passed. This is followed by a stabilization of the
filters, in which a status measurement is carried out,
so that all values are displayed correctly.
8. The display shows the status of the 4 filter cartridges.
It uses a traffic light system.
• Green = Everything is all right.
• Yellow = The values reach a critical range, keep a
replacement filter ready.
• Red = Caution, you should now change the filter.
• Red flashing of the selection buttons = Warning,
change this filter right now. The filter is no longer
effective and will cause the other filters to be used
excessively and the cleaning performance is no
longer guaranteed.
9. The display shows the overview of the resin filter, which
informs you about the water quality being produced by
the HydroPower RO.
Use the buttons next to the display to switch between
`
the filters.
The state is indicated by the colours on the right side of
`
the display.
The colour in the display or the colour of the 4 buttons
`
immediately indicates whether the filter is functioning
properly or has to be replaced.
- The middle part of the display shows the TDS value
(number of dissolved solids) of the incoming water
(from the tap or from the previous filter) and the
outgoing water (after filtering).
- The lower section shows the water flow.
In the lower section of the carbon/sediment combi pre-
`
filter display, the amount of water able to be filtered is
counted down until the filter has to be replaced.
10. Turn the on / off knob back to the centre position.
The HydroPower RO is now ready for use.