Procedure for malfunctions

The following warning messages may appear in the display during operation:
26
Faults and messages
Procedure for malfunctions
Water pressure too low
The inlet pressure from the water line is too low to
`
provide the desired filter performance. The pump
switches off.
Check whether the supply hose is bent or whether
`
there is too little pressure coming from the tap.
Once the problem is resolved, rotate the on / off knob
`
to the red position and back to the green position to
restart the system.
Overheating
Always ensure that the HydroPower RO is well ventilated
and not too close to objects or walls that prevent air
circulation.
1. If the pump motor overheats, the HydroPower RO
switches off automatically.
2. Turn the on / off knob to the red position.
3. Switch off the main power switch.
4. Allow the HydroPower RO to cool down.
5. Loosen the 4 screws on the sides of the HydroPower
RO and remove the front plate.
6. Press the large red button on the pump control.
The pump motor is reset.
`
7. Replace the front plate and tighten the 4 screws.
8. Turn on the main power switch and start the
HydroPower RO with the on/off knob.
The HydroPower RO starts again. If the system does
3
not start, let the HydroPower RO cool down even
further.