3.3 Order structure of R-Series RD4
Temposonics
order code
®
1
2
3
4
5
R
D 4
a
b
c
a Sensor model
R D
4 Detachable sensor electronics
b Design
S Pressure fit flange
M Threaded flange M18×1.5-6g, AF23
C Threaded flange M18×1.5-6g, AF46
T Threaded flange ¾"–16UNF–3A.
D Threaded flange ¾"–16UNF–3A.
c Integral cable of sensor rod
For side cable entry:
D
1 PUR-cable, length 250 mm (9.8 in.)
D
2 PUR-cable, length 400 mm (15.7 in.)
D
3 PUR-cable, length 600 mm (23.6 in.)
For bottom cable entry:
R
2 Single wires with flat connector, length 65 mm (2.6 in.)
R
4 Single wires with flat connector, length 170 mm (6.7 in.)
R
5 Single wires with flat connector, length 230 mm (9.1 in.)
R
6 Single wires with flat connector, length 350 mm (13.8 in.)
d Sensor electronics
S Side cable entry
B Bottom cable entry
*/ Non Standard stroke lengths are available; must be encoded in 5 mm / 0.1 in. increments
5/ Note: Please specify magnet numbers for your sensing application and order separately
TM
6
7
8
9
10
11
d
d
12
13
14
15
16
17
D
5
6
N
1
g
c Stroke length
X
X
X
X M Flange M & C: 0025...5080 mm
X
X
X
.
X
U Flange M & C: 001...200 in.
Standard stroke length (mm)*
Stroke length
25 ... 500 mm
500 ... 750 mm
750...1000 mm
1000...2500 mm
2500...5080 mm
Standard stroke length (in.)*
Stroke length
1...20 in.
20...30 in.
30...40 in.
40...100 in.
100...200 in.
f
Connection type
D
5
6 2 × 4 pin M12 female, 1 × 4 pin M8 male
f
Output
N
1
0
1 EtherNet/IP™
Optional: for multi-position measurement only
(Order additional magnets seperately)
g Magnet number for multi-position measurement
Z
X
X 02...20 magnets
I
6
I
18
19
20
21
22
0
1
g
f
Flange S:
0025...2540 mm
Flange S:
001...100 in.
Ordering steps
5 mm
10 mm
25 mm
50 mm
100 mm
Ordering steps
0.2 in.
0.4 in.
1 in.
2 in.
4 in.
5
Need help?
Do you have a question about the Temposonics R-Series Ethernet/IP and is the answer not in the manual?