replacing v-belts
1.
disConneCt maChine From power!
2.
g0634z only: remove four bolts that secure
fence bracket to machine body, then remove
fence and fence bracket assembly (see
figure 61).
3.
remove cutterhead pulley cover and motor
access panel (see figures 61–62).
Fence Bracket
(g0634z only)
Fence Bracket
mounting Bolts
figure 61. location of fence bracket, cutterhead
pulley cover, and motor access panel (g0634z
shown).
figure 62. Fence, fence bracket, cutterhead
pulley cover, and motor access panel removed
(g0634z shown).
4.
remove belt tension knob (see figure 59).
Model G0634Z/G0634XP (Mfd. Since 01/11)
Cutterhead
pulley Cover
motor access
panel
5.
loosen four motor mount adjustment nuts
and raise motor (see figure 63) to complete-
ly remove v-belt tension. it may help to use a
2x4 as a lever to lift motor.
figure 63. removing v-belt tension for belt
removal/replacement.
6.
remove both belts and replace them with a
new matched set.
7.
lower motor, retighten motor mount adjust-
ment nuts.
8.
rotate pulleys by hand to ensure v-belts are
properly seated in pulleys.
9.
reinstall cutterhead pulley cover and belt
tension knob from steps 3–4 on page 48.
10. g0634z only: reinstall fence and fence
bracket assembly from step 2 on page 48.
11. properly tension v-belts according to
tensioning v-belts on page 48.
12. reinstall motor access panel from step 3 on
page 48.
note: After the first 16 hours of belt life, re-
tension the belts, as they will stretch and seat
during this time.
motor mount
adjustment nuts
(3 of 4)
2x4 lever
-49-