Projecta INTELLI-CHARGE DC/SOLAR BATTERY CHARGER IDC25L Instruction Manual page 12

25 amp, 5 stage switchmode
Table of Contents

Advertisement

HOW TO READ LED DISPLAY
CHARGING
SOLAR
ALTERNATOR
LED Charge Indicators
Charging LED
GREEN Flashing
GREEN Flashing
Solid GREEN
Fault LED Indicators
Charging
LED
Solid RED
Amber
Flashing
Solid RED
RED
Flashing
Solid AMBER
Solid RED
12
MODE
Operating Mode LED
Solar
Alterator
LED
LED
RED
Flashing
Solid RED
RED
Flashing
12V 25A DC 3-Stage
LITHIUM
POWER SUPPLY
Solid BLUE
BLUE Flashing
Solid BLUE
Operating
Fault
Mode LED
The unit is faulty
Bulking charging time out
BLUE
Output battery is reversely
Flashing
Connected
BLUE
Overvoltage is detected
Flashing
at output
BLUE
Output open circuit or
Flashing
dead Battery
Solar Input is reversly
connected
Overvoltage is detected at
Solar Input
Alternator Input is
reversly connected
Overvoltage is detected at
Alterantor
Charging Stage
Soft Start/Bulk Charge
Adsorption Charge
Float Charge
Remedy
Check if there is any output
current from the unit
Auxiliary battery may be
faulty or heavy load is
connected to the battery
for long time
Check output cable
connection
Check auxiliary battery
voltage
Check auxiliary battery
voltage & cable connections
Check Solar input
connection
Check solar panel open
circuit voltage
Check Alternator input
connection
Check vehicle battery
voltage

Hide quick links: