PROTECTIVE FEATURES
Spark-Free Protection
The IDC25L will not start charging the battery (no output) unless the load is securely
connected. It prevents the output leads from sparking due to accidental short circuit
making the charger safer to use around batteries.
Reverse Connection Protection
Reverse connection on input and output terminals does not damage IDC25L internal
circuit. The IDC25L detects reverse connection condition and indicates whether input
or output connection is reversed.
Over and Under Voltage Protection
The charger will automatically shut down if there is an over voltage or under
voltage problem.
Over Temperature Protection
The charger will lower its output current if the temperature of the unit begins
to overheat.
4