Section 4. Programming Reference
Page 4-108
2. If the product of the values entered for "dd" and "ee" are not equal
to or less than the value of "fff" (i.e.,"ffff"
will occur and the symbol will not be printed. It is recommended
that these values each be set to "000" and the printer be allowed
to automatically calculate the optimum values.
3. The values for "dd" and "ee" need to be made larger if the security
level is increased.
4. The maximum data length is 2700 characters, but may be less
depending upon:
- the minimum module dimension ("aa")
- the security level specified by "c".
- the number of data characters
5. The Reference Point of the PDF417 symbol is the upper-left corner.
6. The <ESC>F Sequential Numbering command cannot be used with
this command.
7. The <ESC>E Line Feed command cannot be used with this
command.
8. The Macro and Truncated PDF417 symbols are not supported.
9. The values 00
thru 1F
H
10. This command can be stored in a format.
11. The <ESC>R Rotate command can be used.
12. The print height of the symbol will vary depending upon the data
specified; numeric only, alpha only or alphanumeric.
9001035 Rev. E
"dd" x "ee"), an error
can be specified as print data.
H