Appendix A, B & C - Viking X-9S Installation Instructions And Safety Information

Table of Contents

Advertisement

Appendix (A)
Access Control Connections
Power Connections
The control board provides a 24VDC output to power external devices and controls.
Terminals Connections and Input Functions:
Viking Terminal
"+28V"
---------------------
"GND"
---------------------
"GND"
---------------------
"Radio"
If "Timer" OFF:
If "Timer" ON:
"UL" (see pages 10 & 11)
If input is brief:
If input is longer:
If "UL ADV" is ON:
"Re- Open"
If stopped:
If closing:
"ATG" Anti-Tailgate
Input is received:
Input is released:
"C. Loop"
If not at open limit:
If at open limit:
"Open", "Exit", "Fire" & "Strike"
If stopped:
If closing:
"Stop"
If traveling:
"Close"
If stopped:
If traveling:
!
TECHNICAL TIP:
Each input Terminal (i.e. Radio, Exit, Re-Open, UL) has a corresponding
Status LED that when illuminated indicates an input is currently being provided to the
terminal and the gate is responding accordingly. (See pages 34-35 LED References)
4 0
"C"
"N.O."
Function
DC Positive
---------------
---------------
DC Negative
---------------
Relay Common
Open - Stop - Close
Open / Reopen if closing
Stops gate then Reverses 12 inches
Stops gate, does not reverse
Stops then Opens gate
No function
Stops then Opens gate
Stops gate if closing
Closes gate to prevent tailgating
No function
Prevents gate from Closing
Opens gate
Stops then Opens gate
Stops gate
Closes gate
No function
=
Common
=
Normally Open
Device Terminal
+
"
"
"
"
"C"
"N.O."
"N.O."
"N.O."
"N.O."
"N.O."
"N.O."
"N.O."
"N.O."
VIKING TECHNICAL SUPPORT 1.800.908.0884

Advertisement

Table of Contents
loading

Table of Contents