Viking X-9S Installation Instructions And Safety Information page 40

Table of Contents

Advertisement

TROUBLESHOOTING
LCD Display References
Meaning
LCD MSG
Error Messages
Er PANEL
Indicates that the voltage being provided from the solar panel is too low.
LOW
ER PANEL
Indicates that the voltage being provided from the solar panel is too High.
HIGH
ER SOLAR
Indicates that there is no voltage being provided from the solar panel.
NO PANEL
ERR NO
Solar board can't detect a solar gate operator.
Sol UNIT
ERR CHRG
Potential problem with the Solar Charger.
HIGH
ERR BAT
The battery is low
LOW
ERR FUSE
15 Amp motor fuse is blown on the Master or Single Control Board.
15 AMP
ERR FUSE
15 Amp motor fuse is blown on the SLAVE Module.
15A
S
ERR REFV
One, or more, of the internal reference voltages from the VFlex (Master)
Control Board are incorrect.
WRONG
ERR UL
There is a problem with the required monitored sensor(s) connected
to the "UL" input terminal (pg 10-11).
SENSOR
3 8
VIKING TECHNICAL SUPPORT 1.800.908.0884
Page 39
TS Ref #s
?
?
?
?
?
?
7, 11, 12
7, 11, 12
?