Viking X-9S Installation Instructions And Safety Information page 37

Table of Contents

Advertisement

# LED
9
"C Loop"
10 "Open"
11
"STOP"
12 "Close"
13 "Siren"
14 "Aux. Pwr"
15 "Diagnose" (master)
16
"Close Limit" (master)
17
"Open Limit" (master)
18 "ODS"
19 "Timer"
S1 "Diagnose" (slave)
S2 "Limit Close" (slave)
S3 "Limit Open" (slave)
VIKING TECHNICAL SUPPORT 1.800.908.0884
Status
Meaning
OFF
Normal Condition.
SOLID
An input from a device connected to the C Loop terminal (pg. 31, 40)
OFF
Normal Condition.
SOLID
An input from a device to Exit, Fire, Strike or Open terminal (pg. 30, 40)
OFF
Normal Condition.
SOLID
Control Board is receiving an input from a device connected to the
Stop terminal (pg. 12, 30, 40).
FLASHING
There is a problem with the required monitored sensor(s) connected to
the "UL" input terminal (pg. 10-11)
OFF
Normal Condition.
SOLID
An input from a device connected to the Close terminal (pg. 30, 40)
OFF
Normal Condition.
SOLID
Second consecutive obstruction has been detected. (pg 25, 27)
FLASHING
Batteries are critically low.
OFF
No voltage output on these terminals at the moment.
SOLID
There is 24VDC output on these terminals at the moment.
OFF
Normal Condition
FLASHING
Errors have been detected; Check LCD Display for ERR messages (pg. 38)
OFF
Gate is not at the close limit position.
SOLID
Gate is at the close limit position.
FLASHING
Indicates a problem with the limit switches or wires.
OFF
Gate is not at the open limit position.
SOLID
Gate is at the open limit position.
FLASHING
Indicates a problem with the limit switches or wires.
OFF
Normal Condition.
SOLID
Obstruction event has been detected on the MASTER motor. (pg 25, 27)
FLASHING
Overload event has been detected on the MASTER motor. (pg 25, 27)
OFF
If gate is at the open limit, the Timer to close is turned OFF. (pg 25)
SOLID
Timer to close is ON and counting down to close the gate. (pg 25)
FLASHING
Timer is ON but is not timing out due to a conflicting command. (pg 25)
OFF
Normal Condition
FLASHING
Errors have been detected; Check LCD Display for ERR messages. (pg 38)
SOLID
Obstruction event has been detected on the SLAVE motor. (pg 25, 27)
RAPID FLSH Overload event has been detected on the SLAVE motor. (pg 25, 27)
OFF
Slave gate is not at the close limit position.
SOLID
Slave gate is at the close limit position.
FLASHING
Indicates a problem with the limit switches or wires on the slave operator.
OFF
Slave gate is not at the open limit position.
SOLID
Slave gate is at the open limit position.
FLASHING
Indicates a problem with the limit switches or wires on the slave operator.
TROUBLESHOOTING
Page 39
TS Ref#(s)
9, 10
9, 10
9, 10
16, 22
9, 10
11, 13
6
6
11, 13
11, 13
9, 10
11, 13
11, 13
6
6
3 5

Advertisement

Table of Contents
loading

Table of Contents