Fitting The Winter-Seal; Fitting The Kl Series Cooler - Kaden KC17 Installer Manual

Evaporative air coolers
Hide thumbs Also See for KC17:
Table of Contents

Advertisement

Kaden Installer's Manual
Evaporative Air Coolers

4.2 FITTING THE WINTER-SEAL

The Winter Seal fits directly into the base of the cooler and MUST BE installed before the cooler
is mounted onto the dropper box (preferably while the unit is on the ground).
IMPORTANT
For detailed instructions please refer to "6. Fitting the Winter-Seal" on page 12.

4.3 FITTING THE KL SERIES COOLER

The Cooler should now be mounted into position. Insert the Cooler's air outlet fully into the dropper duct.
Ensure the Cooler base sits fully on the dropper box flange and that the base latching brackets (four) retract over
the flange on both sides of the dropper, to lock it onto the dropper duct.
Fold the end of all four latching brackets in towards the dropper box. Using the hole at the end of the latching
bracket as a guide, drill a 3mm pilot hole through the dropper box only. DO NOT penetrate the plastic chassis.
Four 8g x ½" stainless steel screws should be inserted to secure the four latching brackets to the dropper box.
The Cooler's smallest filter pad and the water supply connection fitting MUST BE on the high side of the roof.
Ensure the 3 pin power plug and lead, together with the Wall Control connection lead, are also fed to the inside
of the dropper duct before retracting the wires and fitting the grommet.