Delta DPM-C501L Operating Manual page 36

Di/do type power meter
Hide thumbs Also See for DPM-C501L:
Table of Contents

Advertisement

DP M- C5 0 1L O pe r a t io n M a nu a l
19
40026
1A
40027
1B
40028
1C
40029
1D
40030
_5
1E
40031
1F
40032 Alarm enable
20
40033 Pickup setpoint (current
21
40034
22
40035
23
40036 Dropout setpoint (current
24
40037
34
40053 Alarm enable
35
40054 Pickup setpoint (line
5 - 4
Stop bit
Stop bit
Modbus address
Reset
Alarm – Over Current
value exceeding this value
triggers alarm)
value below this value
clears alarm)
Alarm – Over Voltage L-L
0: None
1: Even
2: Odd
0: 1
0 – 255
0: None
1: Reset to factory default
2: Reset value of energy
3: Reset alarm times
4: Reset max./min. value
Reserved
Reserved
0: Disable
1: Enable
0.000 – 99999.999
Reserved
0.000 – 99999.999
0: Disable
1: Enable
0.000 – 99999.999
word
2
R/W
word
bit
2
R/W
word
2
R/W
word
2
word
2
R/W
float
A
4
R/W
float
A
4
R/W
word
2
R/W
float
V
4
R/W
W