Delta DPM-MA1121 User Manual

Delta DPM-MA1121 User Manual

Multi-circuit power meter

Advertisement

Quick Links

Industrial Automation Headquarters
Delta Electronics, Inc.
Taoyuan Technology Center
No.18, Xinglong Rd., Taoyuan District,
Taoyuan City 33068, Taiwan
TEL: 886-3-362-6301 / FAX: 886-3-371-6301
Asia
Delta Electronics (Shanghai) Co., Ltd.
No.182 Minyu Rd., Pudong Shanghai, P.R.C.
Post code : 201209
TEL: 86-21-6872-3988 / FAX: 86-21-6872-3996
Customer Service: 400-820-9595
Delta Electronics (Japan), Inc.
Tokyo Office
Industrial Automation Sales Department
2-1-14 Shibadaimon, Minato-ku
Tokyo, Japan 105-0012
TEL: 81-3-5733-1155 / FAX: 81-3-5733-1255
Delta Electronics (Korea), Inc.
Seoul Office
1511, 219, Gasan Digital 1-Ro., Geumcheon-gu,
Seoul, 08501 South Korea
TEL: 82-2-515-5305 / FAX: 82-2-515-5302
Delta Energy Systems (Singapore) Pte Ltd.
4 Kaki Bukit Avenue 1, #05-04, Singapore 417939
TEL: 65-6747-5155 / FAX: 65-6744-9228
Delta Electronics (India) Pvt. Ltd.
Plot No.43, Sector 35, HSIIDC Gurgaon,
PIN 122001, Haryana, India
TEL: 91-124-4874900 / FAX : 91-124-4874945
Delta Electronics (Thailand) PCL.
909 Soi 9, Moo 4, Bangpoo Industrial Estate (E.P.Z),
Pattana 1 Rd., T.Phraksa, A.Muang,
Samutprakarn 10280, Thailand
TEL: 66-2709-2800 / FAX : 662-709-2827
Delta Electronics (Australia) Pty Ltd.
Unit 20-21/45 Normanby Rd., Notting Hill Vic 3168, Australia
TEL: 61-3-9543-3720
Americas
Delta Electronics (Americas) Ltd.
Raleigh Office
P.O. Box 12173, 5101 Davis Drive,
Research Triangle Park, NC 27709, U.S.A.
TEL: 1-919-767-3813 / FAX: 1-919-767-3969
Delta Electronics Brazil
São Paulo Sales Office
Rua Itapeva, 26 - 3°, andar Edificio Itapeva,
One - Bela Vista 01332-000 - São Paulo - SP - Brazil
TEL: 55-12-3932-2300 / FAX: 55-12-3932-237
Delta Electronics International Mexico S.A. de C.V.
Mexico Office
Gustavo Baz No. 309 Edificio E PB 103
Colonia La Loma, CP 54060
Tlalnepantla, Estado de México
TEL: 52-55-3603-9200
DPM-093AJ20-01
*We reserve the right to change the information in this catalogue without prior notice.
EMEA
Headquarters:
Delta Electronics (Netherlands) B.V.
Sales: Sales.IA.EMEA@deltaww.com
Marketing: Marketing.IA.EMEA@deltaww.com
Technical Support: iatechnicalsupport@deltaww.com
Customer Support: Customer-Support@deltaww.com
Service: Service.IA.emea@deltaww.com
TEL: 31(0)40 800 3900
BENELUX:
Delta Electronics (Netherlands) B.V.
De Witbogt 20, 5652 AG Eindhoven, The Netherlands
Mail: Sales.IA.Benelux@deltaww.com
TEL: 31(0)40 800 3900
DACH:
Delta Electronics (Netherlands) B.V.
Coesterweg 45, D-59494 Soest, Germany
Mail: Sales.IA.DACH@deltaww.com
TEL: 49(0)2921 987 0
France:
Delta Electronics (France) S.A.
ZI du bois Challand 2, 15 rue des Pyrénées,
Lisses, 91090 Evry Cedex, France
Mail: Sales.IA.FR@deltaww.com
TEL: 33(0)1 69 77 82 60
Iberia:
Delta Electronics Solutions (Spain) S.L.U
Ctra. De Villaverde a Vallecas, 265 1º Dcha Ed.
Hormigueras – P.I. de Vallecas 28031 Madrid
TEL: 34(0)91 223 74 20
Carrer Llacuna 166, 08018 Barcelona, Spain
Mail: Sales.IA.Iberia@deltaww.com
Italy:
Delta Electronics (Italy) S.r.l.
Via Meda 2–22060 Novedrate(CO)
Piazza Grazioli 18 00186 Roma Italy
Mail: Sales.IA.Italy@deltaww.com
TEL: 39 039 8900365
Russia:
Delta Energy System LLC
Vereyskaya Plaza II, office 112 Vereyskaya str.
17 121357 Moscow Russia
Mail: Sales.IA.RU@deltaww.com
TEL: 7 495 644 3240
Turkey:
Delta Greentech Elektronik San. Ltd. Sti. (Turkey)
Şerifali Mah. Hendem Cad. Kule Sok. No:16-A
34775 Ümraniye – İstanbul
Mail: Sales.IA.Turkey@deltaww.com
TEL: 90 216 499 9910
GCC:
Delta Energy Systems AG (Dubai BR)
P.O. Box 185668, Gate 7, 3rd Floor, Hamarain Centre
Dubai, United Arab Emirates
Mail: Sales.IA.MEA@deltaww.com
TEL: 971(0)4 2690148
Egypt + North Africa:
Delta Electronics
Unit 318, 3rd Floor, Trivium Business Complex, North 90 street,
New Cairo, Cairo, Egypt
Mail: Sales.IA.MEA@deltaww.com
2020-12-14
Delta Multi-Circuit
Power Meter
DPM-MA1121 User Manual
www.deltaww.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DPM-MA1121 and is the answer not in the manual?

Questions and answers

Summary of Contents for Delta DPM-MA1121

  • Page 1 TEL: 7 495 644 3240 Raleigh Office P.O. Box 12173, 5101 Davis Drive, Turkey: Delta Greentech Elektronik San. Ltd. Sti. (Turkey) Şerifali Mah. Hendem Cad. Kule Sok. No:16-A Research Triangle Park, NC 27709, U.S.A. 34775 Ümraniye – İstanbul TEL: 1-919-767-3813 / FAX: 1-919-767-3969 Mail: Sales.IA.Turkey@deltaww.com...
  • Page 2 Delta Multi-Circuit Power Meter DPM-MA1211 User Manual Revision History Ve r s i o n R e v i s i o n D a t e T h e f i r s t v e r s i o n w a s p u b l i s h e d .
  • Page 4: Table Of Contents

    Delta Multi-Circuit Power Meter DPM-MA1121 User Manual Table of Contents Chapter 1 Product Overview Foreword ....................1-2 Outward & Instructions ................1-2 Warming & Criterion ................1-3 Chapter 2 Specifications Electrical Specification................2-2 Communication Specification..............2-3 Operation Interface................. 2-3 2.3.1 Interface Tree ..................
  • Page 5 4.3.2 Data Log Read ..................4-13 Chapter 5 Parameters and Functions Overview of Parameters ................5-2 Chapter 6 Messages of Abnormal Operations Common Malfunction Analysis ..............6-2 6.1.1 Power Meter Does Not Work After Being Electrified ........6-2 6.1.2 Voltage or Current Reading Is Incorrect ..........6-2 6.1.3 Power or Power Factor Reading Is Incorrect, but Voltage and Current Reading Are Correct .........
  • Page 6: Chapter 1 Product Overview

    Chapter 1 Product Overview Table of Contents Foreword ....................1-2 Outward & Instructions ................1-2 Warning & Criterion ................1-3 1 - 1...
  • Page 7: Foreword

    (http://www.delta.com.tw/ia/) to download the latest version when the content specifications are corrected. Outward & Instructions The DPM-MA1121 has a liquid crystal display screen that displays five measurement data per page 1 - 2...
  • Page 8 C ha pt er 1 P r o d uc t o ver v i e w Warning & Criterion  Installation attention  Beware of potential hazards. Wear safety equipment properly when operating this device and follow safety standards and related regulations for operating electric equipment.
  • Page 9 De lta M u lt i- C ir c u i t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l MEMO 1 - 4...
  • Page 10: Chapter 2 Specifications

    Chapter 2 Specifications Table of Contents Electrical Specification ................2-2 Communication Specification ..............2-3 Operation Interface ................2-3 2.3.1 Interface Tree ................2-4 Physical dimensions ................2-6 2 - 1...
  • Page 11: Electrical Specification

    De l ta M u lt i- C ir c ui t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l 2.1 Electrical Specification Accuracy Class Voltage, Current Energy ± 0.5 % ±0.5% Quantity electricity...
  • Page 12: Communication Specification

    Ch a pt er 2 S pec if ic a t i ons 2.2 Communication Specification Communication RS-485 Modbus RTU Baud Rate 1200 / 2400 / 4800 / 9600 / 19200 / 38400 bps 2.3 Operation Interface Display area ENTER key LEFT key RIGHT key UP key...
  • Page 13: Interface Tree

    De l ta M u lt i- C ir c ui t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l 2.3.1 Interface Tree Display UI interface tree-MA1121 2 - 4...
  • Page 14 Ch a pt er 2 S pec if ic a t i ons Setting UI interface tree-MA1121 2 - 5...
  • Page 15: Physical Dimensions

    De l ta M u lt i- C ir c ui t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l 2.4 Physical Dimensions unit : mm[inch.] Rear view : 2 - 6...
  • Page 16: Chapter 3 Installation

    Chapter 3 Installation Table of Contents Installation Method ................. 3-2 3.1.1 Environment ..................3-2 3.1.2 Remind ....................3-2 Basic Test....................3-2 Wiring Instructions ................. 3-3 3.3.1 Circuit Wiring ..................3-3 3.3.2 Communication property..............3-4 3 - 1...
  • Page 17: Installation Method

    De lta M u lt i- C ir c u i t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l 3.1 Installation Method 3.1.1 Environment This product must be placed in the box when it is not in use. If it is not used for the time being, in order to make the product conform to the warranty scope and future maintenance of the company, please pay attention to the following matters during storage.:...
  • Page 18: Wiring Instructions

    AWG 22 ~ 18 2.0 kgf-cm (0.2 N·m) RS-485 AUX.Power, 70℃ or higher AWG 22 ~ 18 5.2 kgf-cm (0.5 N·m) Measured Voltage  Wiring method : DPM-MA1121 DPM-PS01 Use the following symbol in the figure: Symbol Description Hall sensor 3 - 3...
  • Page 19: Communication Property

    De lta M u lt i- C ir c u i t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l 3.3.2 Communication Property  Communication Specifications : 1200、2400、4800、9600、 Max distance of communication 1200 m Baud Rate 19200、38400...
  • Page 20: Chapter 4 Operations

    Chapter 4 Operations Table of Contents 4.1 General Operations ....................4-2 4.1.1 Reading Measured Data ................. 4-2 4.1.2 Power Meter Info Search ................4-4 4.1.3 User Password ....................4-4 4.1.4 General Setting (Input Group)................. 4-5 4.1.4.1 Current Transformer primary ampere (CT Pri) ..........4-5 4.1.4.2 Current Unit (I unt) .................
  • Page 21: General Operations

    De lta M u lt i- C ir c u i t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l General Operations 4.1.1 Reading Measured Data 4.1.1.1 7-segment Display Since the display is a seven-segment LCD, there is a special way to display the English letters, such as the following comparison table: 4.1.1.2 DOWN Quick Search...
  • Page 22 C ha pt er 4 O p er at i o ns Loop 1 Power Loop 2 Power Loop 3 Power Loop 4 Power Loop 5 Power 4.1.1.4 RIGHT Quick Search Press RIGHT to poll the page between the following item parameters On any measurement page, press and hold the LEFT key for 2 seconds and return to the default page (Summary).
  • Page 23: Power Meter Info Search

    De lta M u lt i- C ir c u i t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l 4.1.2 Power Meter Info Search On the meter default page, press and hold the LEFT for 2 seconds to query the relevant information and settings of the meter.
  • Page 24: General Setting (Input Group)

    C ha pt er 4 O p er at i o ns 4.1.4 General Setting (Input Group) 4.1.4.1 Current Transformer primary ampere (CT Pri)  Ampere of Hall sensor primary side, can be set range is 1~9999 A. The default value is 50 A. ...
  • Page 25: Current Low Cut Setting (Locut)

    De lta M u lt i- C ir c u i t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l  Steps of setup are as follows: Press the ENTER key on the parameter page, the setting starts after the content flashes. Use UP and DOWN to select power unit.
  • Page 26: Lcm Backlight (Blight)

    C ha pt er 4 O p er at i o ns Press ENTER on the parameter page and start setting after the number flashes. Press UP or DOWN to select the numeric. Press LEFT key move to next digit. Repeat step 2 to 3 until finishing 4-digits, press ENTER key to save and return to the next parameter page.
  • Page 27: Communication Setting (Comm Group)

    De lta M u lt i- C ir c u i t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l  The power meter uses the number of loops setting, and unused loop parameters will not be displayed. It can be set 1~5 loop.
  • Page 28: Parity Check (Prity)

    C ha pt er 4 O p er at i o ns 4.1.5.3 Parity Check (Prity)  Communication parity check bit setting. The selectable range is N.8.1、N.8.2、O.8.1、E.8.1. The default value is N.8.2.  Steps of setup are as follows: Press the ENTER key on the parameter page, the setting starts after the content flashes. Use UP and DOWN to select parity check.
  • Page 29: Date And Time (Time Group)

    De lta M u lt i- C ir c u i t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l 4.1.5.6 Block Transfer Address Setting (UDFxxP) …… UDF01P UDF20P  Block transfer parameter address setting.
  • Page 30: Initial (Init)

    C ha pt er 4 O p er at i o ns  Time of power meter setting. The selectable range is 00:00:00 ~ 23:59:59.  Steps of setup are as follows: Press ENTER on the parameter page and start setting after the number flashes. Press UP or DOWN to select the numeric.
  • Page 31: Data Log Function Setting

    De lta M u lt i- C ir c u i t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l 4.3.1 Data Log Function Setting The data logging function can set the parameters to be recorded according to required, up to 21 parameters can be set. There are 21 parameters to choose, see Table 4-1 Table 4-1 Parameter...
  • Page 32: Data Log Read

    C ha pt er 4 O p er at i o ns MODBUS Address Data Read(R)/ Item Range Unit BYTE Type Write(W) Modicom Format 400542 0~59 word Minute R / W 400543 0~59 word Second R / W 0: Disable 400544 Logging enable word...
  • Page 33 De lta M u lt i- C ir c u i t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l MODBUS Address Data Read(R)/ Item Range Unit BYTE Type Write(W) Modicom Format 0: Clear all record datas...
  • Page 34 Chapter 5 Parameters and Functions Table of Contents Overview of Parameters .............. 5-2 5 - 1...
  • Page 35: Overview Of Parameters

    De lta M u lt i- C ir c u i t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l 5.1 Overview of Parameters MODBUS Address Data Data Read(R)/ Item Range Unit Type...
  • Page 36 Ch a pt er 5 P ar am ete r s an d Fu nc ti o ns MODBUS Address Data Data Read(R)/ Item Range Unit Type Size(BYTE) Write(W) Modicom Format 400028 Loop 4 Negative energy 0~99999.9 word 400029 400030 Loop 5 Negative energy 0~99999.9 word 400031...
  • Page 37 De lta M u lt i- C ir c u i t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l MODBUS Address Data Data Read(R)/ Item Range Unit Type Size(BYTE) Write(W) Modicom Format...
  • Page 38 Ch a pt er 5 P ar am ete r s an d Fu nc ti o ns MODBUS Address Data Data Read(R)/ Item Range Unit Type Size(BYTE) Write(W) Modicom Format 4. Date & Time :0x7F ~ 0x84 400128 Year 2010~2099 word R / W...
  • Page 39 De lta M u lt i- C ir c u i t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l MODBUS Address Data Data Read(R)/ Item Range Unit Type Size(BYTE) Write(W) Modicom Format...
  • Page 40 Ch a pt er 5 P ar am ete r s an d Fu nc ti o ns MODBUS Address Data Data Read(R)/ Item Range Unit Type Size(BYTE) Write(W) Modicom Format 400535 0~23 word Hour R / W 400536 0~59 word Minute R / W...
  • Page 41 De lta M u lt i- C ir c u i t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l MODBUS Address Data Data Read(R)/ Item Range Unit Type Size(BYTE) Write(W) Modicom Format...
  • Page 42 Ch a pt er 5 P ar am ete r s an d Fu nc ti o ns MODBUS Address Data Data Read(R)/ Item Range Unit Type Size(BYTE) Write(W) Modicom Format 7017 428696 7018 428697 Loop 2 Positive energy 0~99999.9 Float 7019 428698...
  • Page 43 De lta M u lt i- C ir c u i t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l MODBUS Address Data Data Read(R)/ Item Range Unit Type Size(BYTE) Write(W) Modicom Format...
  • Page 44 Chapter 6 Messages of Abnormal Operations Table of Contents 6.1. Common Malfunction Analysis ............... 6-2 6.1.1 Power Meter doesn’t Work after It’s Electrified ......... 6-2 6.1.2 Voltage or Current Reading Is Incorrect ........... 6-2 6.1.3 Power or Power Factor Reading Is Incorrect, but Voltage and Current Reading Are Correct ....................
  • Page 45: Common Malfunction Analysis

    De lta M u lt i- C ir c u i t P o wer Me ter D P M- M A11 2 1 Us er Ma n ua l Common Malfunction Analysis 6.1.1 Power Meter doesn’t Work after It’s Electrified Make sure voltage and other wiring is correct, voltage should be in the functional range.

Table of Contents