ELECTRIC BICYCLE METER KT—LCD8S Product User Manual
Enter P2 parameter setting interface,then
flashes.
P2 is wheel speed pulse signal setting, if wheel generated 1 pulse signal by a
revolution, P2 should be set as1. If wheel generated 6 pulse signals by a revolution, P2
should be set as 6. If users didn't configure the pulse signal system, and then P2 parameter
setting can be 0. The setting range of P2 should be between 0-6, hold
shortly or
button (DOWN) for selection.
Under P2 parameter setting interface, if there's no button operation on the meter
for more than 1 minute, and then the meter will automatically return to display 1,
and the original set parameter will be saved.
Please Note:when P2 parameter is set to be 0, for the built-in clutch motor, there will
be the following defects, when the internal motor rotors stop or the internal rotor speed is
lower than the outer rotor speed, then the speed displayed on the meter is inaccurate!
After finishing P2 parameter setting, press
values, then press

P3 Power Assist Control Mode Setting

P2 parameter setting interface
button (DOWN) to enter P3 parameter setting interface.
- 22 -
P2 parameter column
press
button
button (SW) to save the current set
button (UP)