3
Mechanical Installation
Opening the sensor
Mounting the sensor
Paste the template at desired
location.
Drill as instructed.
4
Electrical Installation
Run the cable through the wire
passage hole just below PCB.
75.5185.04 20070727
From behind, before installation
Insert screws but do not screw
them fully in.
Pass the cable where
indicated.
Position the sensor and tighten the
two screws. Make sure you leave
enough cable to reach the terminal
block near the top of the sensor.
From the front, after installation
or
Optional cable routing:
Notch the cover as shown in
the picture.
Terminal
Connection
1 (Red)
12 to 24 VAC / DC (+)
2 (Black)
12 to 24 VAC / DC (-)
3 (White)
Relay Common
4 (Green)
Relay N.O.
5
Relay N.C.
Note: Input power tolerance is +/- 10% for
AC, and -10% to +30% for DC power.
Wiring connections are as shown above.
Page 3 of 8