Programming Guide - BEA Eagle 10 User Manual

Bea inc. motion sensor user guide
Hide thumbs Also See for Eagle 10:
Table of Contents

Advertisement

6

Programming Guide

The Eagle is equipped with a Motion Tracking Feature (MTF). The MTF is available when the Eagle is used in the uni-
directional mode. The Eagle is factory preset with the MTF ON. MTF is recommended for use in short vestibule areas to
help reduce unwanted door hold-open time. Refer to the Programming Guide to alter this setting. BEA recommends
keeping the MTF enabled for all applications. The detection capabilities perform as follows:
BI-DIRECTIONAL MODE:
• Detection of all motion towards or away from the sensor.
UNI-DIRECTIONAL MODE:
• The detector will work in a uni-directional mode at all times regardless of traffic patterns - detecting only motion moving
toward the sensor.
UNI-DIRECTIONAL MODE WITH MTF: The principle is as follows:
• The detector does NOT activate its relay as long as it detects movement exclusively moving away from the detector. It
acts like the classic unidirectional detector.
• As soon as the Eagle detects movement toward the sensor, it automatically switches to bi-directional mode.
• The Eagle maintains the bi-directional function for approximately 2 seconds following the last detection of motion toward
the door.
• At the end of the 2-second time frame, if the Eagle does not detect any further motion, it switches back to the
unidirectional mode.
Number Keys
Number keys (0 through 9) are used for
assigning a value for a given function
Unlock
Inquire
Lock
To UNLOCK the sensor:
Press the UNLOCK key once. Red LED
flashes quickly
To LOCK the sensor:
Press the LOCK key twice, OR press
once then followed by a 4-digit lock
code. If less than 4 digits, press
lock again after the last digit. LED
goes out when complete.
To INQUIRE the sensor:
Unlock the sensor, press the desired
function key, followed by the
INQUIRY key – the number of
green flashes corresponds to the
value.
Default: 0000
75.5185.04 20070727
?
OR
Adjustment Keys
Plus (+) and minus (-) keys are used for
incremental adjustments to the sensor
Relay Configuration
The relay configuration has 4 possible
output values:
1= Normally Open Relay
2= Normally Closed Relay
3=Continuous Detection
4=Continuous Non-Detection
Default: 1
Default Values
After pressing the DEFAULT VALUE key,
the red LED flashes quickly. After
pressing a number button, the red LED
flashes slowly.
1 = Normal Mounting Height (only for
serial numbers lower than 84000)
2 = Boost Mode, increases sensitivity for
high mount applications.
9 = Restore default values except lock
code (for serial number 84000 and
greater)
Page 6 of 8

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for BEA Eagle 10

This manual is also suitable for:

Eagle

Table of Contents