Download Print this page
BEA Eagle HM Manual
BEA Eagle HM Manual

BEA Eagle HM Manual

Unidirectional activation sensor for high mount doors
Hide thumbs Also See for Eagle HM:

Advertisement

Quick Links

DESCRIPTION
1
2
1.
main connector
2.
wide zone antenna
3.
narrow zone antenna
4.
push buttons
5.
cover

TECHNICAL SPECIFICATIONS

Technology:
Transmitter frequency:
Transmitter radiated power:
Transmitter power density:
Detection mode:
Min. detection speed:
Supply voltage:
Mains frequency:
Max power consumption:
Output:
Max. contact voltage:
Max. contact current:
Max. switching power:
Mounting height:
Degree of protection:
Temperature range:
Dimensions:
Tilt angles:
Material:
Weight:
Cable lenght:
Norm conformity:
* Other use of the device outside of the intended purpose can not be guaranteed by the manufacturer.
75.5611.02 EAGLE HM 20160608
microwave and microprocessor
24.150 GHz
< 20 dBm EIRP
< 5 mW/cm²
motion
2 in/s
12V to 24V AC ±10%; 12V to 24V DC +30% / -10%
50 to 60 Hz
< 2 W
relay (free of potential change-over contact)
42V AC/DC
1A (resistive)
30W (DC) / 60VA (AC)
from 6 ft to 13 ft
IP54
from -4 °F to + 131 °C
4.7 in (L) x 3.1 in (H) x 2.0 in (W)
0° to 90° vertical; -30° to +30° lateral
ABS
7.6 oz
8 ft
R&TTE 1999/5/EC, LVD 2006/95/EC, RoHS 2 2011/65/EU
EAGLE HM
Unidirectional activation sensor for
high mount doors*
3
4
Specifications are subject to changes without prior notice.
Measured in specific conditions.
5
Page 1 of 4

Advertisement

loading

Summary of Contents for BEA Eagle HM

  • Page 1: Technical Specifications

    R&TTE 1999/5/EC, LVD 2006/95/EC, RoHS 2 2011/65/EU Specifications are subject to changes without prior notice. Measured in specific conditions. * Other use of the device outside of the intended purpose can not be guaranteed by the manufacturer. 75.5611.02 EAGLE HM 20160608 Page 1 of 4...
  • Page 2 2 - BLACK - POWER SUPPLY - pull it through. Mount the sensor 3 - WHITE - COM Drill 2 holes for the screws. 4 - GREEN - NO firmly. 5 - GREEN - NC Page 2 of 4 75.5611.02 EAGLE HM 20160608...
  • Page 3 DOOR CONTROL auto open closed closed = the sensor is in standby and does not detect. The LED is OFF. FACTORY VALUES > 2 seconds RESETTING TO FACTORY VALUES: ZONE SIZE ... S, 75.5611.02 EAGLE HM 20160608 Page 3 of 4...
  • Page 4: Access Code

    If you are not an AAADM certifi ed inspector, BEA strongly recommends you have an AAADM certifi ed inspector perform an AAADM inspection and place a valid inspection sticker below the safety information label prior to putting the equipment into operation.