Manual Setup - BEA Eagle 10 User Manual

Bea inc. motion sensor user guide
Hide thumbs Also See for Eagle 10:
Table of Contents

Advertisement

Sensitivity
0 = Minimum Sensitivity
9 = Maximum Sensitivity
Default: 8
Detection Mode
Detection mode offers 3 different levels of
detection:
1 = Bi-Directional
2 = Uni-Directional
3 = Uni-Directional with motion tracking feature
Default: 3
* Every adjustment, when using the infrared remote control, must start with the unlocking function, and end with the
locking function.
7

Manual Setup

If a remote control is not available, only the sensitivity parameter can be adjusted manually, by means of the push
buttons + (Plus) and - (Minus).
The sensor parameters that are not accessible manually will remain at the factory preset values.
Pressing the two push buttons located on the circuit board, simultaneously for at least two seconds, will
restore all default values except the lock code. Previously set lock codes will be retained.
75.5185.04 20070727
Relay Hold Time
Relay hold time refers to the hold time on the
output relay of the Eagle. Values range from 0 to
9.
0 = .5 sec.
1 = 1 sec through 9 = 9 sec in 1 second intervals
Default: 0
Immunity
Immunity helps to reduce the chance of
unwanted detections due to environmental
disturbances.
1 = Reduced
2 = Normal
3 = Increased
4 through 9: enhanced immunity (for highly
reflective environment)
Default: 2
+ Press to increase
sensitivity by one unit.
-
Press to decrease
sensitivity by one unit.