1

MECHANICAL INSTALLATION

BODYMOUNT INSTALLATION
Bodymounts are required for Bodyguard-T installations with one or both of the following circumstances:
reveal (i.e. distance from door face to Bodyguard mounting surface) is less than 3 inches
SuperScan-T is also used
Disregard this sub-section and proceed to "Sensor Preparation" if a Bodymount is not required for this application.
REVEAL:
1
Apply the Bodymount mounting template to the desired location.
2
Drill pilot holes for mounting and wire passage.
3
Partially drill the 2 mounting screws into the pilot holes.
4
Remove the left end cap of the Bodymount for wiring harness routing.
5
Slide extrusion over mounting screws and hand-tighten the screws to secure to the block.
END CAP
SENSOR PREPARATION
1
Remove both end caps
from the sensor by
unscrewing each Phillips-
head screw.
75.5905.06 BODYGUARD-T 20190402
Door
Header
Bodyguard
Door
Face
MOUNTING
SCREW HOLES
WIRE PASSAGE HOLES
2
Slide out each lens at
its respective end of the
sensor.
WITH SUPERSCAN:
MOUNTING TEMPLATE
3
Pull out the center eye
shield from the top, while
rotating out. Do this
carefully, to avoid damage
to the light tube on the
inner side of the shield.
Door
Header
Bodyguard
SuperScan
Door
Face
END CAP
4
Slide the PCB out of the
extrusion and set aside.
Page 3 of 12