3.1 Wiring

Danger of short-circuit and electric shock
Ask a qualified electrician to perform electrical wiring.
If not, short-circuit or electric shock can cause fire or bodily injury.
Danger of electric shock and entanglement
Be sure to turn off electric source on building site before wiring.
If not, it can cause electric shock or bodily injury due to turning objects.
Danger of accident, fire and failure
Be sure to install protective device to protect circuitry. We recommend
overcurrent protective device (rated 15A) to protect branch circuit.
If equipment is not stopped in an emergency, it can cause accident, fire or failure.
Danger of accident, fire or failure
Be sure to install an electric source emergency stop switch (or protective device
that can urgently stop).
If equipment is not stopped in an emergency, it can cause accident, fire or failure.
Danger of fire and electric shock
Install short circuit protective device.
If not, it can cause bodily injury due to fire or electric shock.
Danger of electric fire and electric shock
Install motor protective circuit breaker to protect motor. (refer to chart 1 on page
15)
If not, bodily injury due to electric fire or electric shock can result.
If you have any questions about the selection of protective devices, contact either the
dealer who sold it to you or us.
Danger of short-circuit and electric shock
We recommend an electric wire of larger than 2mm
section area for electric wire (including grounding wire.).
Be careful to avoid voltage drop considering local situation.
If not, it can cause a short-circuit fire and may result in bodily injury from electric shock.
Danger of short-circuit and electric shock
Fit firmly proper round type crimp-style terminal to electric source cable using
crimp tool and connect to motor terminal section.
If not, it can cause short-circuit fire or bodily injury from electric shock due to looseness
or disconnection.
Danger of short-circuit and electric shock
Be sure to fit cable gland to hole of
If not, it can cause short-circuit fire or bodily injury from electric shock.
Danger of electric shock
Connect ground cable to ground terminal in motor terminal box.
If not, it can cause bodily injury from electric shock.
WARNING
2
(more than rated 10A,) cross
22mm at motor terminal box.
-12-
Ask qualified
electrician
Turn off electric
source
Install overcurrent
protective device
Install emergency
stop switch
Install short circuit
protective device
Install motor
protective circuit
breaker to protect
motor
Be careful about
wiring
Use crimp-style
terminal
Protect cable from
being pulled
Be sure to ground

Advertisement