Supermicro SuperServer E300-9D User Manual page 60

1u
Table of Contents

Advertisement

SuperServer E300-9D User's Manual
Port 0 ~ Port 5 sSATA Device Type
Use this feature to specify if the SATA port specified by the user should be connected to a
Solid State Drive or a Hard Disk Drive. The options are Hard Disk Drive and Solid State
Drive.
PCIe/PCI/PnP Configuration
The following information will display:
PCI Bus Driver Version
PCI Devices Common Settings:
Above 4G Decoding (Available if the system supports 64-bit PCI decoding)
Select Enabled to decode a PCI device that supports 64-bit in the space above 4G Address.
The options are Disabled and Enabled.
SR-IOV Support
Use this feature to enable or disable Single Root IO Virtualization Support. The options are
Disabled and Enabled.
MMIO High Base
Use this feature to select the base memory size according to memory-address mapping for
the IO hub. The options are 56T, 40T, 24T, 16T, 4T, and 1T.
MMIO High Granularity Size
Use this feature to select the high memory size according to memory-address mapping for
the IO hub. The options are 1G, 4G, 16G, 64G, 256G, and 1024G.
Maximum Read Request
Use this feature to select the Maximum Read Request size of the PCI-Express device, or
select Auto to allow the System BIOS to determine the value. The options are Auto, 128
Bytes, 256 Bytes, 512 Bytes, 1024 Bytes, 2048 Bytes, and 4096 Bytes.
MMCFG Base
Use this feature to select the low base address for PCI-E adapters to increase base memory.
The options are 1G, 1.5G, 1.75G, 2G, 2.25G, and 3G.
NVMe Firmware Source
Use this feature to select the NVMe firmware to support booting. The default option, Vendor
Defined Firmware, is pre-installed on the drive and may resolve errata or enable innovative
functions for the drive. The other option, AMI Native Support, is offered by the BIOS with a
generic method. The options are Vendor Defined Firmware and AMI Native Support.