Page 2
This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
Installation and maintainance should be performed by experienced technicians only. Please refer to the system specifications page on our Web site for updates on supported memory, processors and operating systems (www.supermicro.com).
E100-8QE model is an extended temperature model, but otherwise similar. Refer to our website for information on operating systems that have been certified for use with the system (www.supermicro.com). For your system to work properly, please follow the links below to download all necessary drivers and utilities, and the user’s manual for your system.
SuperServer E100-8Q User's Manual Storage System storage is a microSDHC memory card up to 32GB in an internal slot. Expansion Slots The system has two internal mini PCI-E 2.0 slots and one ZigBee module socket. Input/Output The front of the chassis includes one USB 2.0 host and one USB 2.0 device port and two LAN ports.
Chapter 1: Introduction Chassis Features The E100-015E is a compact box PC chassis. System Power The system is powered by an external power adapter that connects to the front of the chassis. The external power adapter uses 100-240V AC input, and provides 12V DC, 15W output to the system.
SuperServer E100-8Q User's Manual System Installation and Setup The gateway system is shipped with the processor and the motherboard installed in the chassis. Several steps are necessary to begin using your system. Unpacking the System Inspect the box in which the system was shipped and note if it was damaged. If the system itself shows damage, file a damage claim with the carrier.
Chapter 1: Introduction Serial Number Figure 1-2. Serial Number System Interface The system interface is presented using a host computer attached to the serial port using a terminal emulator, such as PuTTY, to communicate. The front of the chassis includes a power reset button. Reset Button Figure 1-3.
Chapter 2: Advanced Motherboard Setup Chapter 2 Advanced Motherboard Setup This section describes the connections on the A1SQN motherboard and provides pinout definitions. Note that depending on how the system is configured, not all connections are required. The LEDs on the motherboard are also described. Please review the Safety Precautions in Chapter 4 before installing or removing components.
SuperServer E100-8Q User's Manual Processor The E100-8Q features an embedded Intel Quark X1021 single-core 32nm SoC (System-on-a-Chip) processor. This is the next generation secure, low-power Intel Architecture (IA) SoC for deeply embedded applications. The SoC integrates the processor plus all the required hardware components to run off-the-shelf operating systems and to leverage the vast x86 software ecosystem.
Page 16
SuperServer E100-8Q User's Manual Headers/Connectors Connector Description COM1 COM1 Port JTAG Header USB Type B Port I2C Header J102 MicroSD Memory Card Slot JBAT1 RTC Battery Connector JIN1 Alternative Power Input when DC Jack is not used (not recommended) JIO1...
Chapter 2: Advanced Motherboard Setup 2-6 Connector Definitions Ethernet Ports One 10/100Mbps Ethernet port (LAN0) is located on the chassis front to provide network connections. LAN1 is a Bridge LAN port. Universal Serial Bus (USB) One Universal Serial Bus 2.0 port is located on the I/O chassis front. One USB Type B port is located next to the USB 2.0 port.
Page 18
SuperServer E100-8Q User's Manual C Connector I 2 C Header Pin Definitions The I C header, located at J12, controls Pin# Definition and monitors the I C slave devices. See the table on the right for pin definitions. SPI Flash Program Header...
Page 19
Chapter 2: Advanced Motherboard Setup MicroSD Card Slot Insert a microSD memory card into the expansion slot at J102 for additional memory or OS image. Mini PCIe Card Slots One full/half and one half length mini PCIe card slots are located at JPE1 and JPE2. A USB 2.0 interface is available with JPE1.
SuperServer E100-8Q User's Manual Jumpers JP5V and JP3V3 Jumpers JP3V3 Jumper Settings Power output on the JIO1 connector, pins Pin# Definition 19 and 20, can be set. See the tables on JIO1 Pin 19 3.3V Output the right for jumper settings.
Chapter 3: Advanced Chassis Setup Chapter 3 Advanced Chassis Setup This chapter covers the steps required to install or replace components in the E100-015E chassis. The only tool required is a Phillips screwdriver. Review the warnings and precautions listed in the manual before setting up or servicing this chassis.
SuperServer E100-8Q User's Manual Removing the Chassis Covers The user can remove the rear cover to install the microSD memory card, or the top cover to install expansion devices or move jumpers. Removing the Top Cover 1. Power down the system as described in section 3-1.
Chapter 3: Advanced Chassis Setup Adding Radio Antennas If you purchased radio options for your gateway, the internal components and antenna jacks are installed by the manufacturer. To enable radio capabilities, you must add the appropriate antennas. There are two types of antenna: one for WiFi or ZigBee, and one for 3G.
Page 24
SuperServer E100-8Q User's Manual Installing an Antenna 1. For each antenna port, verify that you have the correct antenna type. The dual band antenna is distinguished by two grooves in the screw-on cap (Figure 3-5). The 3G antenna cap has a single groove.
Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. Some warnings may not apply for your system. These warnings may also be found on our web site at http://www.supermicro.com/ about/policies/safety_information.cfm. Warning Definition Warning! This warning symbol means danger.
Page 26
E100-8Q SuperServer User's Manual Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut.
Page 27
Chapter 4: Warning Statements for AC Systems جسذٌة اصابة ًتتسبب ف حالة ٌوكي أى ًاًك ف خطز ًٌٌع هذا الزهز !تحذٌز الذوائز بالوخاطز الٌاجوة عي ي على علن ، ك هعذات تعول على أي قبل أى الكهزبائٍة حىادث أي وقىع وٌع...
E100-8Q SuperServer User's Manual Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. 設置手順書 システムを電源に接続する前に、 設置手順書をお読み下さい。 警告 将此系统连接电源前,请先阅读安装说明。 警告 將系統與電源連接前,請先閱讀安裝說明。 Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
Chapter 4: Warning Statements for AC Systems Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A. サーキッ ト ・ ブレーカー この製品は、 短絡 (過電流) 保護装置がある建物での設置を前提としています。 保護装置の定格が250 V、...
E100-8Q SuperServer User's Manual 경고! 이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지 않도록 해야 합니다. Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V, 20A.
Page 31
Chapter 4: Warning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema. Attention Le système doit être débranché...
E100-8Q SuperServer User's Manual Equipment Installation Warning! Only trained and qualified personnel should be allowed to install, replace, or service this equipment. 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、 交換、 またはサービスを許可 されています。 警告 只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。 警告 只有經過受訓且具資格人員才可安裝、更換與維修此設備。 Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifiziertem Personal gestattet werden.
Chapter 4: Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalificeerd personeel. Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security.
E100-8Q SuperServer User's Manual אזור עם גישה מוגבלת !אזהרה יש להתקין את היחידה באזורים שיש בהם הגבלת גישה. הגישה ניתנת בעזרת .)'כלי אבטחה בלבד (מפתח, מנעול וכד محظورة مناطق ٍنتركُبها ف هذه انىحذة تخصيص تم ،أداة خاصت من خالل استخذاو فقط...
Page 35
Chapter 4: Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
E100-8Q SuperServer User's Manual Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります。 ユニッ トの電源を切るためには、 すべての接続を取り外さなければなりません。 警告 此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。 警告 此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden.
Chapter 4: Warning Statements for AC Systems امداد الطاقة بوحدات عدة اتصاالت جهاز ال يكون لهذا قد الكهرباء عن وحدة ال لعسل كافة االتصاالت يجب إزالة 경고! 이 장치에는 한 개 이상의 전원 공급 단자가 연결되어 있을 수 있습니다. 이 장치에...
Chapter 4: Warning Statements for AC Systems Attention L'équipement doit être installé conformément aux normes électriques nationales et locales. תיאום חוקי החשמל הארצי !אזהרה הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים התקנת المتعلقة المحلية والىطىية قىاويه يجب أن يمتثل لل الكهربائية...
E100-8Q SuperServer User's Manual ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent.
Page 41
Chapter 4: Warning Statements for AC Systems 警告 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 物品太靠近風扇。 Warnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt. ¡Advertencia! Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis.
Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certified cables (that have UL/CSA shown on the code) for any other electrical devices than products designated by Supermicro only. 電源コードとACアダプター 製品を設置する場合、 提供または指定された接続ケーブル、 電源コードとACアダプター...
Page 43
Appareils électroménagers et de loi sur la sécurité Matériel interdit l'utilisation de UL ou CSA câbles certifiés qui ont UL ou CSA indiqué sur le code pour tous les autres appareils électriques que les produits désignés par Supermicro seulement.
Appendix A: System Specifications Appendix A System Specifications Processors One Intel Quark SoC X1021 (CPU TDP support 2.2W), single socket FCBGA393 BIOS 8MB SPI Flash EEPROM Board Support Package Memory Capacity 512 MB of Onboard ECC DDR3 800 MHz memory Micro SDHC up to 32 GB slot Expansion Slots Two Mini-PCIe One ZigBee module socket...
SuperServer E100-8Q User's Manual External Power Adapter 100 to 240V AC input, to 12V DC output, 15W power adapter to supply system Operating Environment Operating Temperature: 0°C ~ 50°C (32°F ~ 122°F) Non-operating Temperature: -40°C to 70°C (-40°F to 158°F)
Page 47
Appendix A: System Specifications This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • This device may not cause harmful interference, and • This device must accept any interference received, including interference that may cause undesired operation.
Page 48
(continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage.
Need help?
Do you have a question about the SuperServer E100-8Q and is the answer not in the manual?
Questions and answers