Balancing Programs Setting; Programs Rapid Setting And Measurements Through Distance- Diameter Caliper Arm - Ravaglioli G3.140R Instruction Manual

Table of Contents

Advertisement

RAVAGLIOLI S.p.A.
At the bottom of the main screen and each screen
described below, there will be coloured rectangles
(Fig. 35 ref. B) located above the icons of identifica-
tion function (Fig. 35 ref. C). These functions are
activated by pressing the appropriate coloured but-
ton on the keypad (Fig. 34 ref. 9). Press the button
(Fig. 35 ref. 3) to display a second page where you
can access the "Technical assistance" menu and the
"Run-out" menu (see Fig. 36).
3
1
2
KEY
1 – User menu
2 – Run-out menu (visible only if the machine is fit
or if the Run-out device is enabled)
3 – Return to previous page
In order to turn off the machine, simply press the "OFF"
switch (Fig. 23 ref. 1).
W H E N T H E E Q U I P M E N T I S
TURNED OFF LOSES ALL THE
M E A S U R E M E N T S A N D T H E
STORED DATA (SIZE, SPINS, US-
ERS, ETC ...). AT RESTARTING,
PRESSING THE BUTTON
THE CASE HAVE NOT YET BEEN
STORED ON THE NEW MEASURES
AFTER THE SWITCHING ON), THE
MACHINE DOES NOT PERFORM
ANY OPERATION.

14.2 Balancing programs setting

The setting of the balancing programs can be per-
formed in two ways:
- through the gauge arm (rapid setting);
- through "Measurement being acquired" screen, ap-
pearing when the
ref. 1).
INSTRUCTION, USE AND
MAINTENANCE MANUAL
G3.140R - GP3.140R - G3.140RS - GP3.140RS
Fig. 36
(IN
button is pressed (Fig. 35
The setting modes are completely different even if
they allow to reach the same result (but with different
times).
14.2.1 Programs rapid setting and meas-
urements through distance-diameter
caliper arm
The use of the distance-diameter caliper arm allows
the rapid automatic wheel balancing program and the
measures entry. From page "Home":
- bring into contact the weights fitting gripper with the
inner part of the rim (1 contact only) to select the
program "STATIC" (see Fig. 37).
Fig. 37
REPEATEDLY BRINGING THE
GAUGE'S ARM (FIG. 38 REF . 1) IN
CONTACT WITH THE MANDREL
(FIG. 38 REF . 2), THE PROGRAM
WILL CYCLE FROM "STATIC" TO
"STATIC 1" TO "2 STATIC" THEN
RETURNING TO THE BEGINNING.
1
1297-M007-1_R
Page 24 of 60
Fig. 38
2
GB

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G3.140rsGp3.140rGp3.140rs