9.3.3 Fitting of external data gauge (standard
for G3.140RS - GP3.140RS versions)
(optional for G3.140R - GP3.140R ver-
sions)
1. Unscrew the fastening screws of the equalizer's
support (Fig. 13 ref. 1), being very careful about
holding the same support.
2. Unscrew the 3 screws (Fig. 13 ref. 2) to the gauge
bracket (Fig. 13 ref. 3) and in the special inserts
placed on the rear side of the frame.
Lock the gauge arm (Fig. 13 ref. 4) by screwing
the 2 screws provided (Fig. 13 ref. 5). Lock these
screws with the nuts (Fig. 13 ref. 6) so that the
mandrel and the gauge arm are levelled out (see
Fig. 14).
Fig. 13
1
3
4
2
3. Also make sure the gauge tip (Fig. 14 ref. 1) is
positioned at the centre of the mandrel.
INSTRUCTION, USE AND
MAINTENANCE MANUAL
G3.140R - GP3.140R - G3.140RS - GP3.140RS
6
Fig. 14
1
4. Connect connector (Fig. 15 ref. 1) of the cable com-
ing from inside the machine to connector (Fig. 15
ref. 2) of the cable coming from the gauge arm. Fit
the section of the cable with the connectors inside
the arm (Fig. 15 ref. 3).
5. Fasten the cable with clamps.
6. Enable the external data gauge and carry out the
device's calibration.