F5 Counter Installation For 60" & 72" Units; Part Number: 9291460 - Delfield F5MC36DV Installation, Operation And Maintenance Manual

F5 series; f15 series. refrigerated display cases
Table of Contents

Advertisement

Section 2
F5 Counter Installation For 60" & 72" Units
Installation Dimensions
Counter Cutout
2 Louver Cutouts
Max distance between counter
top and louver cutout

Part Number: 9291460 11/17

32.62" x 18.62" (83cm x 47cm)
22" x 11" (56cm x 28cm)
4.00" (10cm)
14.50"
14.50"
(37cm)
(37cm)
Cutout
to match
condenser
face
4.0" (10cm)
Max
11.00"
(28cm)
1. Install partitions between F5 refrigerated display case
and other electrical appliances if they are located in the
same cabinet. Partitions must fully extend front to back
and top to bottom.
2. Install a GFCI receptacle a minimum of 14" (36cm) up
from the cabinet bottom inside the partitions.
3. The unit requires airflow to the compressor. Two
louvers are provided with each unit.
NOTE: Any restriction to the proper air flow will void the
compressor warranty.
Louver cut-outs are 22" x 11" (56cm by 28cm).
174in2 (1123cm2) is required at both the intake and
discharge.
Cut-outs are to begin a maximum of 4.00" (10cm)
from the counter-top.
Install louvers on the front and back of the cabinet
or both on the front with a minimum of 12" (30cm)
between them.
Dis-Charge
Air
12.00"
(30cm)
4. Place the condensing unit through the counter cutout.
5. Construct a 14.50" x 12" (37cm x 30cm) air duct (not
provided) connecting the condenser face to the louver.
This will prevent recirculation of discharge air.
Louver
Min
Louver
12.00"
30cm
14.50"
14.50"
(37cm)
(37cm)
Cutout
to match
condenser
face
Installation
Fresh
Air
12.00"
(30cm)
11