Installation must comply with all applicable fire and
health codes in your jurisdiction.
Use appropriate safety equipment during installation
and servicing.
n
Remove all removable panels before lifting and
installing.
n
Do not damage the refrigeration circuit when installing,
maintaining or servicing the unit.
,
The units with LiquiTec technology cold pans contain a
non-toxic eutectic fluid within a sealed inner liner. This
fluid may leak if the tank is punctured so care must be
taken when uncrating and setting in place. The eutectic
fluid is non-toxic and may be flushed down a disposal
drain. Units with a Eutectic Fluid Cold Pan require the
same precautions. The fluid is NOT refillable and loss of
fluid due to a puncture would cause irreparable damage.
If the LiquiTec unit cold pans leak, immediately call the
Delfield service department directly at 1-800-733-8821
not your local service agent.

Location

n
This equipment must be positioned so that the plug is
accessible unless other means for disconnection from
the power supply (e.g., circuit breaker or disconnect
switch) is provided.
n
Adequate means must be provided to limit the
movement of this appliance without depending on or
transmitting stress to the electrical conduit.
Part Number: 9291514 04/17
DANGER
DANGER
Warning
Warning
Caution
Warning
Warning
Section 2

Installation

To avoid instability the installation area must be capable
of supporting the combined weight of the equipment
and product. Additionally the equipment must be level
side to side and front to back.
This equipment is intended for indoor use only. Do not
install or operate this equipment in outdoor areas.
Do not position the air intake vent near steam or heat
exhaust of another appliance.
The location selected for the equipment must meet the
following criteria. If any of these criteria are not met, select
another location.
Units are intended for indoor use only.
The location MUST be level, stable and capable of
supporting the weight of the equipment.
The location MUST be free from and clear of
combustible materials.
Equipment MUST be level both front to back and side to
side.
Position the equipment so it will not tip or slide.
Front casters MUST be locked once positioned.
Recommended air temperature is 41° - 86°F (5° - 30°C).
Proper air supply for ventilation is REQUIRED AND
CRITICAL for safe and efficient operation. Refer to
Clearance Requirements chart on page 6.
Do not obstruct the flow of ventilation air. Make sure the
air vents of the equipment are not blocked.
Do not install the equipment directly over a drain.
Steam rising up out of the drain will adversely affect
operation, air circulation, and damage electrical /
electronic components.
Warning
n
Warning
n
Caution
,
5