Technical Data - Graco Reactor H-VR Repair And Parts Manual

Variable ratio hydraulic proportioner
Hide thumbs Also See for Reactor H-VR:
Table of Contents

Advertisement

Technical Data

Technical Data
Category
Maximum Fluid Working Pressure 3500 psi (24.1 MPa, 241 bar)
Fluid Inlets
Fluid Outlets
Fluid Circulation Ports
Maximum Fluid Temperature
Maximum Output (10 weight oil at
ambient temperature)
Line Voltage Requirement
Amperage Requirement
Heater Power
(A and B heaters total, no hose)
Hydraulic reservoir capacity
Recommended hydraulic fluid
Sound power, per ISO 9614-2
Sound pressure,
1 m from equipment
Weight
Wetted Parts
All other brand names or marks are used for identification purposes and are trademarks of their respective owners.
68
Data
3/4 npsm union in 1 in. npt(f) ball valve
Component A (ISO): #8 (1/2 in.) JIC, with #5 (5/16 in.) JIC adapter
Component B (RES): #10 (5/8 in.) JIC, with #6 (3/8 in.) JIC adapter
1/4 npsm(m), with plastic tubing, 250 psi (1.75 MPa, 17.5 bar) maximum
190°F (88°C)
3.0 gpm (11.4 liter/min) (60 Hz)
230V 3 phase units: 195-264 Vac, 50/60 Hz
400V 3 phase units: 338-457 Vac, 50/60 Hz
See Models, page 3.
See Models, page 3.
3.5 gal. (13.6 liters)
Citgo A/W Hydraulic Oil, ISO Grade 46
90.9 dB(A)
84.0 dB(A)
955 lb (433 kg)
Aluminum, stainless steel, zinc-plated carbon steel, brass, carbide, chrome,
fluoroelastomer, PTFE, ultra-high molecular weight polyethylene, chemically
resistant o-rings
313540L