Circuit Breaker Module - Graco Reactor H-VR Repair And Parts Manual

Variable ratio hydraulic proportioner
Hide thumbs Also See for Reactor H-VR:
Table of Contents

Advertisement

Circuit Breaker Module

1. Turn main power OFF
supply. Turn circuit breakers on to test.
2. Relieve pressure, page 28.
3. Using an ohmmeter, check for continuity across cir-
cuit breaker (top to bottom). If no continuity, trip
breaker, reset, and retest. If still no continuity,
replace breaker as follows:
a. Refer to electrical diagrams and to T
connect wires and remove bad breaker.
b. Install new breaker and reconnect wires.
NOTE: To reference cables and con-
nectors, see the electrical diagrams and
the parts drawings on page 65.
F
. 5. Circuit Breaker Module
IG
313540L
. Disconnect power
3. Dis-
ABLE
809
811
812A
812B
Table 3: Circuit Breakers, see F
Ref.
Size
809
50A
811
40A
812A
50A
812B
50A
813
20A
813
Repair
. 5
IG
Component
Hose/Transformer
Secondary Side
Transformer
Primary
Heater A
Heater B
Motor/Pumps