Graco Reactor H-VR Repair And Parts Manual page 23

Variable ratio hydraulic proportioner
Hide thumbs Also See for Reactor H-VR:
Table of Contents

Advertisement

PROBLEM
Hydraulic pump does not develop
pressure. Low or zero pressure with
screeching noise.
313540L
CAUSE
Pump is not primed or lost its prime.
Screeching noise is characteristic of
cavitation and is normal at initial
startup for a maximum of 30 sec-
onds.
Hydraulic fluid is too hot.
Electric motor operating in wrong
direction for 3 Phase system.
Drive belt loose or broken.
Troubleshooting
SOLUTION
Check electric motor rotation. Both
motor and hydraulic pump must
rotate counterclockwise when viewed
from shaft end. If rotation is incorrect,
reverse leads L1 and L2. See Con-
nect Electrical Cord in Reactor
H-VR Operation manual 313539.
Check dipstick to ensure that hydrau-
lic reservoir is properly filled (see
H-VR Operation manual 313539).
Check that inlet fitting is fully tight, to
ensure no air is leaking into the pump
inlet.
To prime pump, run unit at lowest
pressure setting and slowly increase
pressure. In some cases it may be
necessary to remove motor cover
and drive belt to allow for manual
(counterclockwise) rotation of
hydraulic pump. Turn fan pulley by
hand. Verify oil flow by removing oil
filter to see flow into filter manifold.
Reinstall oil filter. Do NOT operate
unit without a properly installed oil fil-
ter.
If noise continues longer than 30 sec-
onds, press motor
off the motor. Check that the inlet fit-
tings are tight and that the pump has
not lost its prime.
Ensure that the reservoir is properly
serviced. Improve ventilation to allow
more efficient heat dissipation.
Motor must operate counter-clock-
wise from pully end.
Check drive belt condition. Replace if
broken.
key to shut
23